FAN HEATER SW WIRING DIAGRAMS SW12 AND SW22 Preset fan speed, no regulation Connected for low speed, fan position 1 Connected for medium speed, fan position 2 Capacitors in SW SW12/22 1 2 3 4 5 6 7 8 9 N M ~ c˚ SW12 SW22 1 2 3 4 1 2 3 4 2 3 Black Brown Blue 4µF 8µF 2µF 2µF 8µF 16 µF 1µF 3µF L 1 N (L 2 ) 230 V~ 4 1 2 3 4 5 6 7 8 9 N 1 Connected for high speed, fan position 3 Fan heater SW SW12/22 1 2 3 4 5 6 7 8 9 N L1 N (L2) 230 V~ L 1 N (L 2 ) 230 V~ Automatic temperature regulation SWR1 Fan heater SW SW12/22 SW12/22 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 N 9 N SD20 TVV20/25 SD20, actuator on/off, 230V~ Fan heaters 1 2 3 4 5 6 L N 1 2 3 Hi TVV20/25, 2-way valve Lo 1 2 3 SWR, 3-stage change-over switch for control of air flow SWR1 1 - 2 - 3 Man - Auto SWR L 1 N (L 2 ) 230 V~ Diff (1-4)K KRT2800 KRT2800, 2-stage thermostat Thermostat KRT1900 (IP55) and 3-stage change-over switch SWR2 SD20, actuator on/off, 230V~ SD20 SW12/22 1 2 3 4 5 6 7 8 9 N TVV20/25, 2-way valve TVV20/25 1 2 3 SW12/22 1 2 3 4 5 6 7 8 9 N Fan heater SW 2 4 6 KRT1900 SWR2 1 3 5 KRT1900, capillary tube thermostat L1 N (L2) 230 V~ SWR2, 3-stage changeover switch for control of air flow Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se Design and specifications are subject to change without notice. 111

<strong>FAN</strong> <strong>HEATER</strong> <strong>SW</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>SW</strong>12 <strong>AND</strong> <strong>SW</strong>22<br />

<strong>Preset</strong> <strong>fan</strong> speed, no regulation<br />

Connected for low speed, <strong>fan</strong> position 1 Connected for medium speed, <strong>fan</strong> position 2<br />

Capacitors in <strong>SW</strong><br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8 9 N<br />

M ~<br />

c˚<br />

<strong>SW</strong>12<br />

<strong>SW</strong>22<br />

1 2 3 4 1 2 3 4<br />

2<br />

3<br />

Black<br />

Brown<br />

Blue<br />

4µF 8µF 2µF 2µF 8µF 16 µF 1µF 3µF<br />

L 1 N (L 2 )<br />

230 V~<br />

4<br />

1 2 3 4 5 6 7 8 9 N<br />

1<br />

Connected for high speed, <strong>fan</strong> position 3<br />

Fan heater <strong>SW</strong><br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8 9 N<br />

L1 N (L2)<br />

230 V~<br />

L 1 N (L 2 )<br />

230 V~<br />

Automatic temperature regulation <strong>SW</strong>R1<br />

Fan heater <strong>SW</strong><br />

<strong>SW</strong>12/22<br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

9 N<br />

SD20<br />

TVV20/25<br />

SD20, actuator<br />

on/off, 230V~<br />

Fan heaters<br />

1 2 3 4 5 6 L N<br />

1<br />

2<br />

3<br />

Hi<br />

TVV20/25,<br />

2-way valve<br />

Lo<br />

1<br />

2<br />

3<br />

<strong>SW</strong>R,<br />

3-stage change-over<br />

switch for control of air<br />

flow<br />

<strong>SW</strong>R1<br />

1 - 2 - 3<br />

Man - Auto<br />

<strong>SW</strong>R<br />

L 1 N (L 2 )<br />

230 V~<br />

Diff (1-4)K<br />

KRT2800<br />

KRT2800,<br />

2-stage thermostat<br />

Thermostat KRT1900 (IP55) and 3-stage change-over switch <strong>SW</strong>R2<br />

SD20, actuator<br />

on/off, 230V~<br />

SD20<br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

TVV20/25,<br />

2-way valve<br />

TVV20/25<br />

1<br />

2<br />

3<br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

Fan heater <strong>SW</strong><br />

2 4 6<br />

KRT1900<br />

<strong>SW</strong>R2<br />

1 3 5<br />

KRT1900,<br />

capillary<br />

tube<br />

thermostat<br />

L1 N (L2)<br />

230 V~<br />

<strong>SW</strong>R2,<br />

3-stage changeover<br />

switch for<br />

control of air flow<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.<br />

111


<strong>FAN</strong> <strong>HEATER</strong> <strong>SW</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>SW</strong>12 <strong>AND</strong> <strong>SW</strong>22<br />

Thermostat RTE(V) (IP30) and 3-stage regulator <strong>SW</strong>R2<br />

SD20, actuator<br />

on/off, 230V~<br />

SD20<br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

TVV20/25<br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

Fan heater <strong>SW</strong><br />

TVV20/25,<br />

2-way valve<br />

1<br />

2<br />

3<br />

4<br />

5<br />

2 4 6<br />

RTE(V),<br />

electronic thermostat<br />

RTE<br />

L 1 N (L 2 )<br />

230 V~<br />

<strong>SW</strong>R2<br />

1 3 5<br />

<strong>SW</strong>R2,<br />

3-stage regulator<br />

for air flow<br />

3-stage regulator <strong>SW</strong>R2 and economy saving with electronic time switch KUR<br />

SD20, actuator<br />

on/off, 230V~<br />

SD20<br />

TVV20/25<br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

Fan heater <strong>SW</strong><br />

<strong>SW</strong>12/22<br />

1 2 3 4 5 6 7 8<br />

9 N<br />

TVV20/25,<br />

2-way valve<br />

1<br />

2<br />

3<br />

Lo<br />

Hi<br />

Diff (1-4)K<br />

KRT2800<br />

1<br />

2<br />

3<br />

1<br />

3<br />

2<br />

L<br />

N<br />

KUR<br />

<strong>SW</strong>R2<br />

2 4 6<br />

1 3 5<br />

<strong>SW</strong>R2,<br />

3-stage regulator<br />

for air flow<br />

KRT2800,<br />

2-stage<br />

thermostat<br />

L 1 N (L 2 )<br />

230 V~<br />

KUR,<br />

electronic<br />

time switch<br />

112<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.


<strong>FAN</strong> <strong>HEATER</strong> <strong>SW</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>SW</strong>32 <strong>AND</strong> <strong>SW</strong>33<br />

<strong>Preset</strong> <strong>fan</strong> speed, no regulation<br />

c˚ M~<br />

Orange<br />

Black<br />

Blue<br />

Brown<br />

Z2 Z1 U2 U1TK TK<br />

Fan heater <strong>SW</strong><br />

N (L 2 ) L 1<br />

230 V~<br />

Thermostat KRT1900 (IP55) and 5-stage regulator RE3 or RE7<br />

SD20, actuator<br />

on/off, 230V~<br />

TVV20/25,<br />

2-way valve<br />

SD20<br />

TVV20/25<br />

1<br />

2<br />

3<br />

<strong>SW</strong>32/33<br />

<strong>SW</strong>32/33<br />

Z2 Z1 U2 U1 TK TK<br />

Z2 Z1 U2 U1 TK TK<br />

L 1 L 2 ~ NN ~<br />

Fan heater <strong>SW</strong><br />

Fan heaters<br />

KRT1900<br />

RE3/7<br />

KRT1900,<br />

capillary tube<br />

thermostat<br />

L 1 N (L 2 )<br />

230 V~<br />

RE3/RE7,<br />

5-stage change-over<br />

switch for air flow<br />

5-stage regulator RE3 or RE7 and economy saving with electronic time switch KUR<br />

SD20, actuator<br />

on/off, 230V~<br />

SD20<br />

<strong>SW</strong>32/33<br />

Z2 Z1 U2 U1 TK TK<br />

TVV20/25<br />

<strong>SW</strong>32/33<br />

Z2 Z1 U2 U1 TK TK<br />

Fan heater <strong>SW</strong><br />

TVV20/25,<br />

2-way valve<br />

1<br />

2<br />

3<br />

Lo<br />

Hi<br />

Diff (1-4)K<br />

KRT2800<br />

1<br />

2<br />

3<br />

1<br />

3<br />

2<br />

L<br />

N<br />

KUR<br />

RE3/7<br />

L 1 L 2 ~ NN ~<br />

RE3/RE7,<br />

5-stage change-over<br />

switch for air flow<br />

KRT2800,<br />

2-stage<br />

thermostat<br />

L 1 N (L 2 )<br />

230 V~<br />

KUR,<br />

electronic<br />

time switch<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.<br />

113

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!