17.01.2015 Views

GPS-X Technical Reference

GPS-X Technical Reference

GPS-X Technical Reference

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Influent Models 88<br />

Figure 5-27 - Selection of Feed Chemical and Set-up of Chemical Properties<br />

The COD chemical dosage object has a built-in flow rate controller. The controller is<br />

useful for controlling the feed rate of COD based on a user defined controlled variable.<br />

Acid Dosage Object<br />

The acid dosage object is only available in the MANTIS2LIB. The acid dosage object<br />

uses the acidfeed model (Figure 5-28). The acid dosage object allows user to select the<br />

type of acid used in the feed. Three acids HCl, H 2SO 4 and HNO 3 are available for<br />

selection from the Composition > Feed Chemical Details menu (Figure 5-29). The<br />

Feed Chemical Details menu is as shown in Figure 5-30. For the selected chemical, two<br />

input parameters of % purity and density of chemical solution at the selected %-purity are<br />

required. If HCl or H 2SO 4 is selected, the state variable of other anion (sana) is set to the<br />

equivalent dosed amount. If HNO 3 is the selected acid then, the state variable of Nitrate-<br />

N (snoa) is set to an equivalent concentration.<br />

Figure 5-28 - Models in Acid Dosage Influent Object<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>