Operating Cost Models 362<br />

<strong>GPS</strong>-X can simulate two different aeration methods - mechanical and diffused air. If<br />

mechanical aeration is chosen, an aeration power (kW) is entered. If diffused aeration is<br />

chosen, the power requirement is calculated as shown in Equation 6.27 and Equation<br />

6.28 in Chapter 6.<br />

The wire power is multiplied by the energy price ($/kWh), and then integrated over time<br />

to determine the total cost for aeration energy during the simulation<br />

Blower Energy Cost<br />

Energy required for the pumping of water and wastewater is modelled in <strong>GPS</strong>-X using<br />

the following equation:<br />

Equation 13.1<br />

P blower =<br />

1.4161 ∗ 10 −5 ∗ (T + 273.15) ∗ q air ∗ [( P 0.283<br />

out<br />

P<br />

) − 1]<br />

in<br />

η b<br />

P in = P atm − P inlet,loss<br />

P out = P atm + 9.81 ∗ h diff + P diff,loss<br />

Where:<br />

P blower<br />

= Blower power, kW<br />

T = Air temperature, ºC<br />

q air<br />

P out<br />

P in<br />

= Air Flow rate, m3/d<br />

= Air pressure at discharge, kPa<br />

= Air pressure at the inlet, kPa<br />

η b = Blower efficiency, -<br />

P atm<br />

P inlet,loss<br />

h diff<br />

P diff,loss<br />

= Atmospheric pressure, kPa<br />

= inlet pressure loss, kPa<br />

= diffuser submergence, m<br />

= head loss in piping and diffuser, kPa<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>