<strong>GPS</strong>-X Objects 30<br />

If this logical variable is false, then the user can specify the initial reactor volume at the<br />

start of the simulation. As a consequence of this, the user can specify the starting volume<br />

as full by two ways:<br />

1. Either setting the logical variable as “true”; or<br />

2. By setting the variable as “false” and manually specifying the starting volume as<br />

equal to the maximum tank volume.<br />

From Equation 2.1, the concentration of a conservative material in objects with volume<br />

relative to its influent concentration can be calculated as shown in the following equations:<br />

Equation 2.5<br />

where:<br />

X = conservative component concentration (g/m 3 )<br />

Q = flow rate (m 3 /d)<br />

t = time (d)<br />

Q in = influent stream<br />

Q out = effluent stream<br />

X out = effluent concentration (g/m 3 )<br />

At steady-state, the time derivatives are zero and Equation 2.5 becomes:<br />

Equation 2.6<br />

If the SRT is defined as:<br />

Equation 2.7<br />

where:<br />

SRT = solids retention time (d)<br />

V = volume (m 3 )<br />