Other Models 298<br />

PUMPING STATION<br />

The noreact model for Pumping Station is modified for the fixed water level option.<br />

In the fixed water level option, the pumping flow rate used to be equal to the input flow rate. One<br />

of the issues with the model was that in a flow scheme with pump recycle, the pumped flows gets<br />

unbounded.<br />

In the variable water level option, the main problem was the undefined flow rates for the steady<br />

state calculations.<br />

Both of these problems are addressed in the new model. In the new model, the fixed level option<br />

is made equivalent to the continuous pumping while the variable water level option is considered<br />

equivalent to intermittent pumping with water level control.<br />

Model Data Input<br />

The new input form is as shown in Figure 11-1:<br />

Figure 11-1 - Pumping Station Menu<br />

Continuous pumping<br />

This variable controls whether continuous pumping or intermittent water level controlled<br />

pumping is used.<br />

Average daily pump flow rate<br />

This flow rate is used for continuous pumping rate and also in the calculation of steady<br />

state calculations when intermittent pumping is selected.<br />

Low volume for pump OFF<br />

This variable defines the volume in the tank below which the pump operates at minimum<br />

pumping capacity.<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>