227 Attached-Growth Models<br />

Liquid Film Concentrations<br />

This provides the liquid film state variables for each horizontal section of the trickling<br />

filter, from top (section 1) to bottom (section 6).<br />

2D Variables<br />

This is used for plotting both the filter horizontal sections and biofilm layers variables<br />

using the 3D bar chart or grayscale outputs. Examples are shown in Figure 7-8. From left<br />

to right are the liquid layer and five biofilm layers. In the 3D bar chart, the top of the<br />

filter is located in the foreground, and the bottom of the filter in the background. In the<br />

greyscale graph, the six horizontal trickling filter horizontal sections are shown from top<br />

to bottom (i.e. top layer of the filter is shown at the top of the graph).<br />

Figure 7-8 - 2D Variables<br />