17.01.2015 Views

GPS-X Technical Reference

GPS-X Technical Reference

GPS-X Technical Reference

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

203 Suspended Growth Models<br />

Entering Oxygenator Power<br />

Estimate the SAE<br />

The SAE is estimated based on the correlation provided by Praxair. The expression is<br />

valid for SOTE in the range of 86% to 100%. If the user specified SOTE is less than 80%<br />

then the SAE is bounded at 7.11 kg/kWh.<br />

Equation 6.63<br />

where:<br />

SAE = Specific aerator energy (wire), kgO 2/kW-hr<br />

SOTE = Standard oxygen transfer rate (%)<br />

Estimate the SOTR<br />

The mechanical power requirement is estimated using the following expression:<br />

Equation 6.69<br />

where:<br />

P mechanical<br />

= mechanical power (kW)<br />

SAE = mechanical aerator oxygen transfer rate (kg O 2/kW h)<br />

CF 2 = conversion factor<br />

η motor<br />

= motor efficiency<br />

Estimate OTR<br />

The OTR is calculated using Equation 6.24<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!