Estimate Oxygen Transfer Rate (OTR) at Field Conditions in g/d<br />

Equation 6.12<br />

Suspended Growth Models 198<br />

Estimate Standard Oxygen Transfer Rate (SOTR) in g/d<br />

Equation 6.13<br />

Airflow at Standard Conditions in m 3 /d<br />

The gas flow is calculated using Equation 6.15:<br />

Equation 6.15<br />

where:<br />

molfr O2 = mole fraction of O 2 in user-defined air (mole/mole)<br />

MW O2<br />

= molecular weight of O 2 (32 g/mole)<br />

P user = density of user-defined air (g/m 3 )<br />

MW user<br />

= average molecular weight of user-defined air (g/mole)<br />