197 Suspended Growth Models<br />

Oxygen Mass Transfer Coefficient at Field Conditions Calculations<br />

<strong>GPS</strong>-X provides four different ways to specify the user inputs to estimate gas-liquid<br />

transfer in the open basin HPO system.<br />

1. Direct specification of the clean water at K La at 20°C<br />

2. Specifying the gas flow rate at standard condition of 1 atm pressure and 20°C<br />

temperature<br />

3. Specify the wire point input of the oxygenator<br />

4. Use a DO controller<br />

In each of the above, the user has the option of specifying SOTE. The default value for<br />

SOTE for high purity oxygen is considered to be 90%.<br />

Entering KLa Directly<br />

Estimate K La at field conditions<br />

The KLa at field conditions is calculated using Equation 6.11:<br />

Equation 6.11<br />

where:<br />

K La T<br />

= mass transfer coefficient at temperature T in °C (1/day)<br />

K La 20 = mass transfer coefficient at 20°C<br />

θ<br />

= temperature correction factor (default value<br />

<strong>GPS</strong>-X is 1.024)<br />

α = wastewater correction factor for K La 20<br />

F =diffuser fouling factor (default value in <strong>GPS</strong>-X is 1.0)<br />

T<br />

= wastewater temperature (°C)<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>