195 Suspended Growth Models<br />

The vapour pressure of water at the liquid temperature is determined using the Antoine<br />

equation (Felder and Rousseau, 1986):<br />

Equation 6.6<br />

where:<br />

A, B, C = Antoine coefficients<br />

T<br />

= wastewater temperature (°C)<br />

The depth correction factor for oxygen saturation is calculated as follows:<br />

Equation 6.59<br />

where:<br />

d<br />

= depth of the tank<br />

The DO saturation concentration at 20°C and 1 atm is calculated as follows:<br />

Equation 6.10<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>