173 Suspended Growth Models<br />

With the normal SBR object, the seven phases making up this cycle are fixed in sequence<br />

(the order is shown in the form). The total length of all seven phases must not exceed the<br />

cycle time specified. If the total length of all seven phases adds up to less than the cycle<br />

time, the tank will be idle until the end of the cycle time. If it adds up to a value greater<br />

than the cycle time, the remaining time and/or phases beyond the cycle time will be<br />

ignored. A phase can be disabled by setting its length to zero.<br />

Figure 6-19 - Advanced SBR Operational Parameter<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>