165 Suspended Growth Models<br />

The maximum fouling resistance and fouling rate constant can be found in the<br />

Input Parameters > Physical – Membrane > form. They are selected based on data in<br />

Merlo et al. (2000). The model assumes that the fouling material is completely removed<br />

during a recovery clean so that the time for fouling starts after each recovery clean.<br />

Model Parameters – Operational<br />

The membrane operational parameters can be set in the<br />

Input Parameters > Operational – Membrane form, shown in Figure 6-14.<br />

Figure 6-14 – Membrane Operational Parameters Menu<br />

The trans-membrane pressure from Equation 6.1 is set in this menu, along with the<br />

MBR backwashing options (including the frequency, duration and flow rate of the<br />

backwash). Alternatively, the level controller can be used, which sets the backwash<br />

length to the amount of time required to refill the tank. If the level controller is on and<br />

the tank is already full, no backwashing will take place.<br />