Blower Cost Sub-Section (Operating Cost Form)<br />

Suspended Growth Models 120<br />

The blower cost sub-section can be accessed by right-clicking on most biological objects<br />

and selecting Input Parameters > Operating Cost. The <strong>GPS</strong>-X form is shown in Figure<br />

6-7. The available parameters are described below.<br />

Combined blower/motor efficiency: Specifies the overall efficiency of the<br />

mechanical aeration equipment (i.e. blowers, motors, coupling, and gear box).<br />

The default value is 0.7 or 70 % efficiency.<br />

Pressure drop in inlet filters and piping to blower: Specifies the pressure drop<br />

in the inlet filters and piping to the blowers for the purposes of calculating the<br />

wire power supplied to the mechanical aeration equipment. The default value is<br />

1 kPa.<br />

Pressure drop in piping and diffuser downstream of blower: Specifies the<br />

pressure drop in the piping and diffusers downstream of the blowers for the<br />

purposes of calculating the wire power supplied to the mechanical aeration<br />

equipment. The default value is 7 kPa.<br />

Figure 6-7 - Blower Cost Form<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>