17.01.2015 Views

GPS-X Technical Reference

GPS-X Technical Reference

GPS-X Technical Reference

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Suspended Growth Models 114<br />

Alpha factor (fine bubble): Specifies the value of the wastewater correction factor for<br />

the fine bubble K La. The default value is 0.6.<br />

Alpha factor (coarse bubble): Specifies the value of the wastewater correction factor<br />

for the coarse bubble K La. The default value is 0.8.<br />

Alpha factor (jet): Specifies the value of the wastewater correction factor for the jet<br />

K La. The default value is 0.85.<br />

Alpha factor (user-defined): Specifies the value of the wastewater correction factor for<br />

the user-defined K La. The default value is 0.6<br />

Fouling constant: Diffuser fouling factor. Default value is 1 (i.e. no fouling)<br />

Depth correction factor for user-defined (Fine Bubble/Coarse Bubble): When the<br />

user-defined diffuser type is being used, this parameter selects whether Equation 6.8 or<br />

Equation 6.9 is used to calculate the depth correction factor for the DO saturation<br />

concentration.<br />

Oxygen Transfer Efficiency (SOTE) Sub-Section (Under More…)<br />

SOTE type (Constant/Correlation): Specifies whether the SOTE is set by the user or<br />

calculated by a correlation. The correlation used depends on the diffuser type selected.<br />

Standard oxygen transfer efficiency: When the SOTE type is set to constant, this<br />

value is used for the SOTE.<br />

Diffuser submergence: Specifies the depth of submergence of the diffusers.<br />

Method of specifying diffuser setup (Enter Number of Diffusers/Enter Diffuser<br />

Density): Allows the user to either specify the number of diffusers or the diffuser<br />

density (diffuser area/tank area). It is important to enter the diffuser density or the<br />

number of diffusers if an SOTE correlation is being used or the user requires <strong>GPS</strong>-X to<br />

display accurate values of the airflow per diffuser and the number of diffusers per unit<br />

area.<br />

Diffuser density (diffuser area/tank area): When the method of specifying the diffuser<br />

setup has been selected as diffuser density, this parameter allows the user to enter the<br />

diffuser density as a fraction or a percentage. Diffuser densities between 5 % and 25 %<br />

are typical.<br />