103 Suspended Growth Models<br />

The SOTR is calculated as follows:<br />

Equation 6.21<br />

The mechanical power is calculated using the SOTR:<br />

Equation 6.22<br />

where:<br />

P mechanical<br />

= mechanical power (kW)<br />

η = mechanical aerator oxygen transfer rate (1.75 kg O2/kW h)<br />

CF 2 = conversion factor (24,000)<br />

The default α value for mechanical aeration in <strong>GPS</strong>-X is 0.9.<br />

Entering Airflow<br />

The airflow can be entered at either standard or field conditions. At standard conditions,<br />

the user has three options:<br />

1. U.S. Standard Conditions:<br />

a. Temperature = 20°C<br />

b. Pressure = 1 atm<br />

c. Relative humidity = 36%<br />

2. European Standard Conditions:<br />

a. Temperature = 0°C<br />

b. Pressure = 1 atm<br />

c. Relative humidity = 0%<br />

3. User-Defined Standard Conditions:<br />

The user must specify the properties (mole fraction of O2 in air, density,<br />

molecular weight, and exponent in blower power equation). When using the<br />

user-defined standard conditions option, <strong>GPS</strong>-X uses a Henry’s law<br />

correction to adjust the value of C * st.<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!