Suspended Growth Models 100<br />

The α correction factor can be specified along the length of the aeration tank in the case<br />

of a plug flow unit process.<br />

<strong>GPS</strong>-X calculates other useful process variables from the standard and field K La as<br />

detailed below:<br />

Oxygen Transfer Rate (OTR) at Field Conditions in g/d<br />

Equation 6.12<br />

Standard Oxygen Transfer Rate (SOTR) in g/d<br />

Equation 6.13<br />

Airflow at Standard Conditions in m 3 d<br />

Equation 6.14<br />

where:<br />

SOTE<br />

CF 1<br />

= standard oxygen transfer efficiency (as a fraction)<br />

= conversion factor to account for the density, molecular weight,<br />

and O2 mole fraction of the standard air<br />

(U.S. Standard = 277.6533841; European Standard =<br />

300.495893)<br />

<strong>GPS</strong>-X <strong>Technical</strong> <strong>Reference</strong>