<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

7 Block OUTPUTS<br />

Function description<br />

OUTPUTS PULSE/FREQUENCY OUTPUT (1...2) CONFIGURATION (FREQUENCY)<br />

VALUE F LOW<br />

(4204) ! Note!<br />

This function is not available unless the FREQUENCY setting was selected in the<br />

OPERATION MODE function (4200).<br />

Use this function to assign a variable to the start value frequency (4202).<br />

The value can be higher or lower than the value assigned to the VALUE F HIGH. Positive<br />

and negative values are permissible, depending on the measured variable in question<br />

(e.g. mass flow). You define a measuring range by defining the VALUE F LOW and<br />

VALUE F HIGH values.<br />

User input:<br />

5-digit floating-point number<br />

Factory setting:<br />

0 [kg/h] or 0 [kg/l] or –50 [°C]<br />

! Note!<br />

• For a graphic illustration VALUE F LOW see the VALUE F HIGH function (4205).<br />

• Note that values with different signs cannot be entered for VALUE F LOW<br />

and VALUE F HIGH, if SYMMETRY is the setting selected for the MEASURING<br />

MODE function (4206). In this case, the message “INPUT RANGE EXCEEDED”<br />

appears on the display.<br />

• The appropriate unit is taken from the UNIT MASS FLOW (0400),<br />

UNIT VOLUME FLOW (0402), UNIT CORRECTED VOLUME FLOW (0404), UNIT<br />

DENSITY (0420), UNIT REFERENCE DENSITY (0421) or<br />

UNIT TEMPERATURE (0422) function (see p. 17 to p. 21).<br />

VALUE F HIGH<br />

(4205) ! Note!<br />

This function is not available unless the FREQUENCY setting was selected in the<br />

OPERATION MODE function (4200).<br />

Use this function to assign a variable to the end value frequency (4203).<br />

The value can be higher or lower than the value assigned to the VALUE F LOW. Positive<br />

and negative values are permissible, depending on the measured variable in question<br />

(e.g. mass flow). You define a measuring range by defining the VALUE F LOW and<br />

VALUE F HIGH values.<br />

User input:<br />

5-digit floating-point number<br />

Factory setting:<br />

Depends on nominal diameter [kg/h] or 2 [kg/l] or 200 [°C]<br />

! Note!<br />

Note that values with different signs cannot be entered for VALUE F LOW<br />

and VALUE F HIGH, if SYMMETRY is the setting selected for the MEASURING MODE<br />

function (4206). In this case, the message “INPUT RANGE EXCEEDED” appears on the<br />

display.<br />

125<br />

100<br />

Freq.<br />

0<br />

➀<br />

➁<br />

Q<br />

m = VALUE f min<br />

n = VALUE f max<br />

A0001279<br />

(continued on next page)<br />

Issue/Rev. 0.2 (12/12) MN0M023 • Page 77