7 Block OUTPUTS <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

Function description<br />

OUTPUTS CURRENT OUTPUT (1...3) CONFIGURATION<br />

Detailed explanations and<br />

information<br />

(continued)<br />

2. Defined measuring range (m–n): m and n have different signs<br />

➀<br />

20<br />

mA<br />

4<br />

0 0<br />

➁<br />

Q<br />

Flow a (—) outside, b (- -) within the measuring range.<br />

A0001272<br />

➁<br />

Q<br />

0 + +<br />

➀<br />

a<br />

b<br />

t<br />

A0001273<br />

• STANDARD<br />

a (—): The flow components outside the scaled measuring range cannot be taken into<br />

account for signal output.<br />

A fault message is generated (# 351...354, current range) and the current output<br />

responds in accordance with the parameter settings in the function FAILSAFE MODE<br />

(4006).<br />

b (): The current output signal is proportional to the measured variable assigned.<br />

mA<br />

t<br />

A0001274<br />

• SYMMETRY<br />

This option is not available under these circumstances, because the 0_4 mA value and<br />

the 20 mA value have different signs.<br />

• PULSATING FLOW<br />

Flow components outside the measuring range are buffered, balanced and output after<br />

a maximum delay <strong>of</strong> 60 seconds.<br />

mA<br />

A<br />

S<br />

S=A<br />

t<br />

A0001275<br />

TIME CONSTANT<br />

(4005)<br />

Use this function to enter a time constant defining how the current output signal reacts to<br />

severely fluctuating measured variables, either very quickly (enter a low time constant) or<br />

with damping (enter a high time constant).<br />

User input:<br />

fixed-point number 0.01...100.00 s<br />

Factory setting:<br />

1.00 s<br />

Page 70 • MN0M023<br />