7 Block OUTPUTS <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

Function description<br />

OUTPUTS CURRENT OUTPUT (1...3) CONFIGURATION<br />

VALUE 0_4 mA<br />

(continued)<br />

Parameter setting example A:<br />

1. VALUE 0_4 mA (4002) = not equal to zero flow (e.g. –5 kg/h)<br />

VALUE 20 mA (4003) = not equal to zero flow (e.g. 10 kg/h) or<br />

2. VALUE 0_4 mA (4002) = not equal to zero flow (e.g. 100 kg/h)<br />

VALUE 20 mA (4003) = not equal to zero flow (e.g. –40 kg/h)<br />

and<br />

MEASURING MODE (4004) = STANDARD<br />

When you enter the values for 0/4 mA and 20 mA, the working range <strong>of</strong> the measuring<br />

device is defined. If the effective flow drops below or exceeds this working range<br />

(see Fig. m), a fault/notice message is generated (#351-354, current range) and the<br />

current output responds in accordance with the parameter settings in the function<br />

FAILSAFE MODE (4006).<br />

1) mA<br />

2) mA<br />

20<br />

4<br />

20<br />

4<br />

Q<br />

Q<br />

-5 0 10 -40 0 100<br />

➀ ➀ ➀ ➀<br />

Parameter setting example B:<br />

1. VALUE 0_4 mA (4002) = equal to zero flow (e.g. 0 kg/h)<br />

VALUE 20 mA (4003) = not equal to zero flow (e.g. 10 kg/h) or<br />

2. VALUE 0_4 mA (4002) = not equal to zero flow (e.g. 100 kg/h)<br />

VALUE 20 mA (4003) = equal to zero flow (e.g. 0 kg/h)<br />

and<br />

MEASURING MODE (4004) = STANDARD<br />

A0001262<br />

When you enter the values for 0/4 mA and 20 mA, the working range <strong>of</strong> the measuring<br />

device is defined. In doing so, one <strong>of</strong> the two values is configured as zero flow<br />

(e.g. 0 kg/h).<br />

If the effective flow drops below or exceeds the value configured as the zero flow, no<br />

fault/notice message is generated and the current output retains its value.<br />

If the effective flow drops below or exceeds the other value, a fault/notice message is<br />

generated (#351-354, current range) and the current output responds in accordance with<br />

the parameter settings in the function FAILSAFE MODE (4006).<br />

1) mA<br />

20<br />

2) mA<br />

4 20 4<br />

Q<br />

Q<br />

0 10<br />

➀<br />

0 100<br />

➀<br />

A0001264<br />

Deliberately only one flow direction is output with this setting and flow values in the<br />

other flow direction are suppressed.<br />

Parameter setting example C:<br />

MEASURING MODE (4004) = SYMMETRY<br />

The current output signal is independent <strong>of</strong> the direction <strong>of</strong> flow (absolute amount <strong>of</strong> the<br />

measured variable). The 0_4 mA value m and the 20 mA value n must have the same<br />

sign (+ or-). The “20 mA VALUE” o (e.g. backflow) corresponds to the mirrored 20 mA<br />

VALUE n (e.g. flow).<br />

mA<br />

20<br />

4<br />

0<br />

➂ ➀ ➁<br />

Q<br />

A0001249<br />

ASSIGN RELAY (4700) = FLOW DIRECTION<br />

With this setting e.g. the flow direction output via a switching contact can be made.<br />

Parameter setting example D:<br />

MEASURING MODE (4004) = PULSATING FLOWpage 68 ff.<br />

Page 66 • MN0M023<br />

Issue/Rev. 0.2 (12/12)