5 Block USER INTERFACE <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />
5.4 Group INFORMATION LINE<br />
5.4.1 Function group CONFIGURATION<br />
USER INTERFACE C CONTROL CAA<br />
<br />
MAIN LINE CCA<br />
<br />
ADDITIONAL LINE CEA<br />
<br />
INFORMATION LINE CGA CONFIGURATION 260<br />
Function description<br />
USER INTERFACE INFORMATION LINE CONFIGURATION<br />
1<br />
2<br />
-<br />
Esc<br />
+<br />
E<br />
3<br />
A0001253<br />
1 = main line, 2 = additional line, 3 = information line<br />
ASSIGN<br />
(2600)<br />
In this function, a value to be displayed is assigned to the information line (bottom line in<br />
the local display). This value is displayed during normal operation.<br />
Options:<br />
OFF<br />
MASS FLOW<br />
MASS FLOW IN %<br />
VOLUME FLOW<br />
VOLUME FLOW IN %<br />
CORRECTED VOLUME FLOW<br />
CORRECTED VOLUME FLOW IN %<br />
DENSITY<br />
REFERENCE DENSITY<br />
TEMPERATURE<br />
MASS FLOW BARGRAPH IN %<br />
VOLUME FLOW BARGRAPH IN %<br />
CORRECTED VOLUME FLOW BARGRAPH IN %<br />
ACTUAL CURRENT (1...3)<br />
ACTUAL FREQUENCY (1...2)<br />
TOTALIZER (1...3)<br />
TAG NAME<br />
OPERATING/SYSTEM CONDITIONS<br />
FLOW DIRECTION READING<br />
ACTUAL CURRENT INPUT<br />
Factory setting:<br />
OPERATING/SYSTEM CONDITIONS<br />