17.01.2015 Views

Proline Promass 83E/F/O Description of Device Functions - FMC ...

Proline Promass 83E/F/O Description of Device Functions - FMC ...

Proline Promass 83E/F/O Description of Device Functions - FMC ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

5 Block USER INTERFACE<br />

Function description<br />

USER INTERFACE ADDITIONAL LINE CONFIGURATION<br />

ASSIGN<br />

(continued) ! Note!<br />

The options given in the BATCHING s<strong>of</strong>tware package always refer to the batching<br />

selected (“BATCH # 1”, “BATCH # 2”, etc.) in the BATCH SELECTOR function<br />

(page 147). Example: If BATCH # 1 was selected in the BATCH SELECTOR function<br />

(7200), then only the values from BATCH # 1 (batch name, batch quantity etc.) can be<br />

displayed.<br />

Advanced options with optional s<strong>of</strong>tware package CONCENTRATION:<br />

TARGET MASS FLOW<br />

% TARGET MASS FLOW<br />

TARGET VOLUME FLOW<br />

% TARGET VOLUME FLOW<br />

CORRECTED TARGET VOLUME FLOW<br />

CARRIER MASS FLOW<br />

% CARRIER MASS FLOW<br />

CARRIER VOLUME FLOW<br />

% CARRIER VOLUME FLOW<br />

CORRECTED CARRIER VOLUME FLOW<br />

% BLACK LIQUOR<br />

° BAUME<br />

° API<br />

° PLATO<br />

° BALLING<br />

° BRIX<br />

OTHERS (_ _ _ _ flexible concentration)<br />

Advanced options with optional s<strong>of</strong>tware package ADVANCED DIAGNOSIS:<br />

MASS FLOW DEVIATION<br />

DENSITY DEVIATION<br />

REFERENCE DENSITY DEVIATION<br />

TEMPERATURE DEVIATION<br />

TUBE DAMPING DEVIATION<br />

ELECTRODYNAMIC SENSOR DEVIATION<br />

OPERATING FREQUENCY FLUCTUATION DEVIATION<br />

TUBE DAMPING FLUCTUATION DEVIATION<br />

100% VALUE<br />

(2401) ! Note!<br />

This function is not available unless one <strong>of</strong> the following was selected in the ASSIGN<br />

function (2400):<br />

• MASS FLOW IN %<br />

• VOLUME FLOW IN %<br />

• CORRECTED VOLUME FLOW IN %<br />

• MASS FLOW BARGRAPH IN %<br />

• VOLUME FLOW BARGRAPH IN %<br />

• CORRECTED VOLUME FLOW BARGRAPH IN %<br />

Use this function to define the flow value to be shown on the display as the 100% value.<br />

User input:<br />

5-digit floating-point number<br />

Factory setting:<br />

10 kg/s, 10 l/s or 10 Nl/s<br />

Issue/Rev. 0.2 (12/12) MN0M023 • Page 45