5 Block USER INTERFACE <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

5.2.2 Function group MULTIPLEX<br />

USER INTERFACE C CONTROL CAA<br />

<br />

MAIN LINE CCA CONFIGURATION 220<br />

<br />

MULTIPLEX 222<br />

Function description<br />

USER INTERFACE MAIN LINE MULTIPLEX<br />

ASSIGN<br />

(2220)<br />

Use this function to define the second reading to be displayed in the main line alternately<br />

(every 10 seconds) with the value defined in the ASSIGN function (2200).<br />

Options (standard):<br />

OFF<br />

MASS FLOW<br />

MASS FLOW IN %<br />

VOLUME FLOW<br />

VOLUME FLOW IN %<br />

CORRECTED VOLUME FLOW<br />

CORRECTED VOLUME FLOW IN %<br />

DENSITY<br />

REFERENCE DENSITY<br />

TEMPERATURE<br />

ACTUAL CURRENT (1...3)<br />

ACTUAL FREQUENCY (1...2)<br />

TOTALIZER (1...3)<br />

ACTUAL CURRENT INPUT<br />

Factory setting:<br />

OFF<br />

Advanced options with optional s<strong>of</strong>tware package BATCHING:<br />

BATCH NAME (“BATCH # 1” or “BEER 330”, etc.)<br />

BATCH QUANTITY (overall quantity to be batched)<br />

BATCH COUNTER (batching processes carried out)<br />

BATCH SUM (effective total batching quantity)<br />

! Note!<br />

The options given in the BATCHING s<strong>of</strong>tware package always refer to the batching<br />

selected (“BATCH # 1”, “BATCH # 2”, etc.) in the BATCH SELECTOR function<br />

(page 147). Example: If BATCH # 1 was selected in the BATCH SELECTOR function<br />

(7200), then only the values from BATCH # 1 (batch name, batch quantity etc.) can be<br />

displayed.<br />

Advanced options with optional s<strong>of</strong>tware package CONCENTRATION:<br />

TARGET MASS FLOW<br />

% TARGET MASS FLOW<br />

TARGET VOLUME FLOW<br />

% TARGET VOLUME FLOW<br />

CORRECTED TARGET VOLUME FLOW<br />

CARRIER MASS FLOW<br />

% CARRIER MASS FLOW<br />

CARRIER VOLUME FLOW<br />

% CARRIER VOLUME FLOW<br />

CORRECTED CARRIER VOLUME FLOW<br />

% BLACK LIQUOR<br />

°BAUME<br />

°API<br />

°PLATO<br />

°BALLING<br />

°BRIX<br />

OTHERS (_ _ _ _ flexible concentration)<br />

(continued on next page)<br />