Proline Promass 83E/F/O Description of Device Functions - FMC ...
Proline Promass 83E/F/O Description of Device Functions - FMC ...
Proline Promass 83E/F/O Description of Device Functions - FMC ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />
4 Block QUICK SETUP<br />
• The display returns to the function QUICK SETUP BATCHING/DOSING (1005), if you press<br />
the ESC key combination during parameter interrogation.<br />
• At the start <strong>of</strong> the Setup, general device parameters are optimally configured for measuring signal<br />
processing and output response.<br />
• Then you can enter the specific batching parameters, starting with the options list “Batching<br />
1...6”. In this way, by running through the Setup menu a number <strong>of</strong> times, up to six different<br />
batching parameter sets (incl. special naming) can be created and called up as necessary.<br />
"<br />
• In order to enjoy full functionality, it is advisable to let the display parameters be set<br />
automatically. This means that the lowest display line is configured as the batching menu.<br />
S<strong>of</strong>tkeys are displayed which can be used to start or stop the batching process in the HOME<br />
position. In this way, the measuring device can be fully deployed as a “batch controller”.<br />
Caution!<br />
By running the Setup, certain device parameters are optimally set for discontinuous operation.<br />
Should the measuring device be used for continuous flow measurement at a later time, we<br />
recommend you to rerun the “COMMISSIONING” or the “PULSATING FLOW” Setup.<br />
Settings for the Batching Setup menu:<br />
Fct. code Function name Suggested settings <strong>Description</strong><br />
Call up through the function matrix:<br />
B QUICK SETUP QUICK SETUP<br />
see p. 25<br />
BATCHING/DOSING<br />
1005 QUICK SETUP BATCHING/DOSING YES see p. 26<br />
Settings (functions with a gray background are set automatically):<br />
6400 ASSIGN LOW FLOW CUT OFF Mass see p. 122<br />
6402 ON-VALUE LOW FLOW CUT OFF Table value see p. 122<br />
6403 OFF-VALUE LOW FLOW CUT OFF 50% see p. 122<br />
6603 FLOW DAMPING 0 seconds see p. 133<br />
6404 PRESSURE SHOCK SUPPRESSION 0 seconds see p. 123<br />
7200 BATCH SELECTOR BATCH #1 see p. 147<br />
7202 BATCH NAME BATCH #1 see p. 147<br />
7201 ASSIGN BATCH VARIABLE Mass see p. 148<br />
7203 BATCH QUANTITY 0 see p. 148<br />
7204 FIX COMPENSATION QUANTITY 0 see p. 149<br />
7205 COMPENSATION MODE OFF see p. 149<br />
7208 BATCH STAGES 1 see p. 152<br />
7209 INPUT FORMAT Value input see p. 152<br />
4700 ASSIGN RELAY BATCHING VALVE 1 see p. 101<br />
4780 TERMINAL NUMBER Output (display only) see p. 107<br />
7220 OPEN VALVE 1 0% or 0 [unit] see p. 153<br />
7240 MAXIMUM BATCHING TIME 0 seconds (Off) see p. 158<br />
7241 MIN. BATCHING QUANTITY 0 seconds see p. 159<br />
7242 MAX. BATCHING QUANTITY 0 seconds see p. 160<br />
2200 ASSIGN (Main line) BATCH NAME see p. 40<br />
2220 ASSIGN (Multiplex main line) Off see p. 42<br />
2400 ASSIGN (Additional line) BATCH DOWNWARDS see p. 44<br />
2420 ASSIGN (Multiplex additional line) Off see p. 47<br />
2600 ASSIGN (Info line) BATCHING KEYS see p. 50<br />
2620 ASSIGN (Multiplex info line) Off see p. 53<br />
Issue/Rev. 0.2 (12/12) MN0M023 • Page 33