4 Block QUICK SETUP <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

4.4 Batching Setup menu<br />

This Setup menu guides the user systematically through all the device functions that have to be<br />

adjusted and configured for batching operation.<br />

The Setup menu settings result in a (simple) one-stage batching process. The parameters for<br />

additional settings, e.g. for automatic compensation <strong>of</strong> after-runs or multistage batching must be<br />

manually set in the function matrix.<br />

XXX.XXX.XX<br />

-<br />

+<br />

E<br />

+<br />

Quick Setup<br />

B<br />

HOME-POSITION<br />

E+<br />

QS 1005<br />

Batching/Dosing<br />

ON-Value<br />

Low flow cut <strong>of</strong>f<br />

6402<br />

Flow<br />

damping<br />

6603<br />

Pressure shock<br />

suppression<br />

6404<br />

Batch<br />

Selector<br />

Batch<br />

Name<br />

Batch<br />

Quantity<br />

7200<br />

7201<br />

7203<br />

Fix 7204<br />

Compensation Quantity<br />

Select<br />

Relay 1<br />

Output<br />

Relay 2<br />

Assign<br />

Relay<br />

4700<br />

Terminal No.<br />

4780<br />

YES<br />

Batch<br />

Supervision<br />

NO<br />

Max. Batch<br />

Time<br />

7240<br />

YES<br />

Autom. Configuration<br />

Display<br />

NO<br />

Locked<br />

PRESET<br />

Batch quantity<br />

Access Customer<br />

Automatic parameterization<br />

<strong>of</strong> the display<br />

Quit Quick Setup<br />

A0004644-en<br />

! Note!<br />

• This Setup menu is only available when the optional s<strong>of</strong>tware package BATCHING is installed in<br />

the measuring device. By means <strong>of</strong> the order option, the s<strong>of</strong>tware package can already be<br />

installed in the measuring device when delivered from the factory or it can be ordered at a later<br />

date from Endress + Hauser and installed as an optional s<strong>of</strong>tware package.<br />