<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

10 Block SPECIAL FUNCTION<br />

10.3.9 Function group OPERATING FREQUENCY FLUCTUATION<br />

SPECIAL FUNCTION H ADVANCED DIAGNOSIS HEA CONFIGURATION 740<br />

<br />

ACQUISITION 741<br />

<br />

MASS FLOW 742<br />

<br />

DENSITY 743<br />

<br />

REFERENCE DENSITY 744<br />

<br />

TEMPERATURE 745<br />

<br />

TUBE DAMPING 746<br />

<br />

ELEC.-DYN. SENSORS 747<br />

<br />

OPERATING FREQ.<br />

FLUCT.<br />

748<br />

Function description<br />

SPECIAL FUNCTION ADVANCED DIAGNOSIS OPERATING FREQUENCY FLUCTUATION<br />

REFERENCE VALUE<br />

OPERATING<br />

FREQUENCY<br />

FLUCTUATION<br />

(7480)<br />

The reference value for the fluctuation <strong>of</strong> the operating frequency appears on the display.<br />

Display:<br />

5-digit floating-point number, Hz<br />

OPERATING<br />

FREQUENCY<br />

FLUCTUATION<br />

(7481)<br />

The measured fluctuation <strong>of</strong> the operating frequency appears on the display.<br />

Display:<br />

5-digit floating-point number, Hz<br />

MINIMUM VALUE<br />

(7482)<br />

The lowest value <strong>of</strong> the operating frequency fluctuation since the saved values were last<br />

reset appears on the display.<br />

Display:<br />

5-digit floating-point number, Hz<br />

MAXIMUM VALUE<br />

(7483)<br />

The highest value <strong>of</strong> the operating frequency fluctuation since the saved values were last<br />

reset appears on the display.<br />

Display:<br />

5-digit floating-point number, Hz<br />

OPERATING<br />

FREQUENCY<br />

FLUCTUATION HISTORY<br />

(7484)<br />

The last ten values <strong>of</strong> the operating frequency fluctuation since the saved values were last<br />

reset appear on the display.<br />

Display:<br />

5-digit floating-point number, Hz<br />

OPERATING<br />

FREQUENCY<br />

FLUCTUATION<br />

DEVIATION<br />

(7485)<br />

This function displays the deviation between the measured deviation <strong>of</strong> the operating<br />

frequency and the reference values (FACTORY or USER) selected in the function SELECT<br />

REFERENCE CONDITION (7402) see page 166.<br />

Display:<br />

5-digit floating-point number, Hz<br />

Issue/Rev. 0.2 (12/12) MN0M023 • Page 175