<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

10 Block SPECIAL FUNCTION<br />

10.3.6 Function group TEMPERATURE<br />

SPECIAL FUNCTION H ADVANCED DIAGNOSIS HEA CONFIGURATION 740<br />

<br />

ACQUISITION 741<br />

<br />

MASS FLOW 742<br />

<br />

DENSITY 743<br />

<br />

REFERENCE DENSITY 744<br />

<br />

TEMPERATURE 745<br />

Function description<br />

SPECIAL FUNCTION ADVANCED DIAGNOSIS TEMPERATURE<br />

! Note!<br />

The appropriate unit is taken from the function UNIT TEMPERATURE (0422) (see page 21).<br />

REFERENCE VALUE<br />

TEMPERATURE<br />

(7450)<br />

TEMPERATURE<br />

(7451)<br />

MINIMUM VALUE<br />

(7452)<br />

The reference value for the temperature appears on the display.<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

The currently measured temperature appears on the display.<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

The lowest temperature value since the saved values were last reset appears on the<br />

display.<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

MAXIMUM VALUE<br />

(7453)<br />

The highest temperature value since the saved values were last reset appears on the<br />

display.<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

TEMPERATURE HISTORY<br />

(7454)<br />

The last ten temperature values since the saved values were last reset appear on the<br />

display.<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

TEMPERATURE<br />

DEVIATION<br />

(7455)<br />

This function displays the deviation between the currently measured temperature and the<br />

reference values (FACTORY or USER), see page 166, selected in the function SELECT<br />

REFERENCE CONDITION (7402).<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

WARNING LEVEL<br />

(7456) ! Note!<br />

This function is not available unless ON was selected in the WARNING MODE function<br />

(7403).<br />

Use this function to specify a limit value for the temperature. A notice message is<br />

generated if the limit value is exceeded.<br />

User input:<br />

0...99999 °C<br />

Factory setting:<br />

100 °C<br />