<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />
10 Block SPECIAL FUNCTION<br />
10.3.4 Function group DENSITY<br />
SPECIAL FUNCTION H ADVANCED DIAGNOSIS HEA CONFIGURATION 740<br />
<br />
ACQUISITION 741<br />
<br />
MASS FLOW 742<br />
<br />
DENSITY 743<br />
Function description<br />
SPECIAL FUNCTION ADVANCED DIAGNOSIS DENSITY<br />
! Note!<br />
The appropriate unit is taken from the function UNIT DENSITY (0420) (see page 20).<br />
REFERENCE VALUE<br />
DENSITY<br />
(7430)<br />
The reference value for the density appears on the display.<br />
Display:<br />
5-digit floating-point number, incl. units<br />
DENSITY<br />
(7431)<br />
The measured density appears on the display.<br />
Display:<br />
5-digit floating-point number, incl. units<br />
MINIMUM VALUE<br />
(7432)<br />
The lowest density value since the saved values were last reset appears on the display.<br />
Display:<br />
5-digit floating-point number, incl. units<br />
MAXIMUM VALUE<br />
(7433)<br />
The highest density value since the saved values were last reset appears on the display.<br />
Display:<br />
5-digit floating-point number, incl. units<br />
DENSITY HISTORY<br />
(7434)<br />
DENSITY DEVIATION<br />
(7435)<br />
The last ten density values since the saved values were last reset appear on the display.<br />
Display:<br />
5-digit floating-point number, incl. units<br />
This function displays the deviation between the measured density and the reference<br />
values (FACTORY or USER), see page 166, selected in the function SELECT REFERENCE<br />
CONDITION (7402).<br />
Display:<br />
5-digit floating-point number, incl. units<br />
WARNING LEVEL<br />
(7436) ! Note!<br />
This function is not available unless ON was selected in the WARNING MODE function<br />
(7403).<br />
Use this function to specify a limit value for the density. A notice message is generated if<br />
the limit value is exceeded.<br />
User input:<br />
0...99999 [%]<br />
Factory setting:<br />
100%<br />
Issue/Rev. 0.2 (12/12) MN0M023 • Page 169