<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />
10 Block SPECIAL FUNCTION<br />
Function description<br />
SPECIAL FUNCTION BATCHING FUNCTION CONFIGURATION<br />
FIX COMPENSATION<br />
QUANTITY<br />
(7204)<br />
Use this function to specify a positive or negative compensation quantity. The<br />
compensation quantity balances out a constant, system-related incorrect quantity. This<br />
can be caused, for example, by a pump over-running or by the closing time <strong>of</strong> a valve.<br />
The compensation quantity is determined by the system operator. A negative<br />
compensation quantity must be specified for overbatching and a positive compensation<br />
quantity for underbatching.<br />
! Note!<br />
The compensation quantity affects batching quantity only and does not affect the after<br />
run compensation.<br />
User input:<br />
Floating-point number with sign (depends on nominal diameter)<br />
Factory setting:<br />
0 [unit]<br />
! Note!<br />
• If the entry range is not sufficient for the compensation quantity, the batching quantity<br />
may have to be adjusted.<br />
• The appropriate unit is taken from the function group SYSTEM UNITS (ACA),<br />
(see page 17).<br />
COMPENSATION MODE<br />
(7205)<br />
Use this function to determine whether the after run quantity or a fixed compensation<br />
quantity should be taken into account at the next batching.<br />
Options:<br />
OFF<br />
MODE 1<br />
MODE 2<br />
Factory setting:<br />
OFF<br />
! Note!<br />
The pressure shock suppression must be switched <strong>of</strong>f if MODE 1 or MODE 2 is selected<br />
in this function (see function PRESSURE SHOCK SUPPRESSION (6404) on page 123).<br />
Detailed explanations and information<br />
When batching using the optional s<strong>of</strong>tware package BATCHING, process-related variable<br />
after run quantities or incorrect quantities can be determined and balanced out (by<br />
computer) by means <strong>of</strong> various functions. This ensures a high level <strong>of</strong> accuracy<br />
throughout the entire batching range.<br />
• Response when OFF is selected:<br />
The batching ends as soon as the quantity specified in the function BATCH<br />
QUANTITY (7203) has been achieved. If after running occurs, this is not recorded and<br />
is not taken into consideration during the next batching. In this way, in the event <strong>of</strong><br />
process-related after running, the effective batched quantity is generally larger than the<br />
batching quantity specified.<br />
• Response when MODE 1 is selected:<br />
For short batchings and for batching cycles that follow on quickly from one other.<br />
Batching ends before the quantity specified in the function BATCH QUANTITY (7203)<br />
is achieved and the after run quantity is recorded. The exact batching switch-<strong>of</strong>f time<br />
is calculated based on the previous after run quantities.<br />
The number <strong>of</strong> after run quantities which are to influence the calculation can be<br />
specified in the functions AVERAGING DRIP (7207) and CALCULATION MODE<br />
(7206). The after run quantity in MODE 1 is determined between the switch-<strong>of</strong>f point<br />
and the first undershooting <strong>of</strong> the low flow cut <strong>of</strong>f. Any subsequent fluid movements<br />
are not taken into account.<br />
(continued on next page)<br />
Issue/Rev. 0.2 (12/12) MN0M023 • Page 149