<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

10 Block SPECIAL FUNCTION<br />

Function description<br />

SPECIAL FUNCTION BATCHING FUNCTION CONFIGURATION<br />

FIX COMPENSATION<br />

QUANTITY<br />

(7204)<br />

Use this function to specify a positive or negative compensation quantity. The<br />

compensation quantity balances out a constant, system-related incorrect quantity. This<br />

can be caused, for example, by a pump over-running or by the closing time <strong>of</strong> a valve.<br />

The compensation quantity is determined by the system operator. A negative<br />

compensation quantity must be specified for overbatching and a positive compensation<br />

quantity for underbatching.<br />

! Note!<br />

The compensation quantity affects batching quantity only and does not affect the after<br />

run compensation.<br />

User input:<br />

Floating-point number with sign (depends on nominal diameter)<br />

Factory setting:<br />

0 [unit]<br />

! Note!<br />

• If the entry range is not sufficient for the compensation quantity, the batching quantity<br />

may have to be adjusted.<br />

• The appropriate unit is taken from the function group SYSTEM UNITS (ACA),<br />

(see page 17).<br />

COMPENSATION MODE<br />

(7205)<br />

Use this function to determine whether the after run quantity or a fixed compensation<br />

quantity should be taken into account at the next batching.<br />

Options:<br />

OFF<br />

MODE 1<br />

MODE 2<br />

Factory setting:<br />

OFF<br />

! Note!<br />

The pressure shock suppression must be switched <strong>of</strong>f if MODE 1 or MODE 2 is selected<br />

in this function (see function PRESSURE SHOCK SUPPRESSION (6404) on page 123).<br />

Detailed explanations and information<br />

When batching using the optional s<strong>of</strong>tware package BATCHING, process-related variable<br />

after run quantities or incorrect quantities can be determined and balanced out (by<br />

computer) by means <strong>of</strong> various functions. This ensures a high level <strong>of</strong> accuracy<br />

throughout the entire batching range.<br />

• Response when OFF is selected:<br />

The batching ends as soon as the quantity specified in the function BATCH<br />

QUANTITY (7203) has been achieved. If after running occurs, this is not recorded and<br />

is not taken into consideration during the next batching. In this way, in the event <strong>of</strong><br />

process-related after running, the effective batched quantity is generally larger than the<br />

batching quantity specified.<br />

• Response when MODE 1 is selected:<br />

For short batchings and for batching cycles that follow on quickly from one other.<br />

Batching ends before the quantity specified in the function BATCH QUANTITY (7203)<br />

is achieved and the after run quantity is recorded. The exact batching switch-<strong>of</strong>f time<br />

is calculated based on the previous after run quantities.<br />

The number <strong>of</strong> after run quantities which are to influence the calculation can be<br />

specified in the functions AVERAGING DRIP (7207) and CALCULATION MODE<br />

(7206). The after run quantity in MODE 1 is determined between the switch-<strong>of</strong>f point<br />

and the first undershooting <strong>of</strong> the low flow cut <strong>of</strong>f. Any subsequent fluid movements<br />

are not taken into account.<br />

(continued on next page)<br />

Issue/Rev. 0.2 (12/12) MN0M023 • Page 149