<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

10 Block SPECIAL FUNCTION<br />

10.2 Group BATCHING FUNCTION<br />

10.2.1 Function group CONFIGURATION<br />

SPECIAL FUNCTION H BATCHING FUNCTION HCA CONFIGURATION 720<br />

Function description<br />

SPECIAL FUNCTION BATCHING FUNCTION CONFIGURATION<br />

BATCH SELECTOR<br />

(7200)<br />

Use this function to select a batching specification. There are six different batching<br />

specifications available by means <strong>of</strong> which different batchings can be defined.<br />

Options:<br />

BATCH # 1 (or the name which was defined for batching specification 1 in the function<br />

BATCH NAME (7201) )<br />

BATCH # 2 (or the name which was defined for batching specification 2 in the function<br />

BATCH NAME (7201) )<br />

BATCH # 3 (or the name which was defined for batching specification 3 in the function<br />

BATCH NAME (7201) )<br />

BATCH # 4 (or the name which was defined for batching specification 4 in the function<br />

BATCH NAME (7201) )<br />

BATCH # 5 (or the name which was defined for batching specification 5 in the function<br />

BATCH NAME (7201) )<br />

BATCH # 6 (or the name which was defined for batching specification 6 in the function<br />

BATCH NAME (7201) )<br />

Factory setting:<br />

BATCH #1<br />

! Note!<br />

• By selecting a batching specification and its related settings (explained below), up to 6<br />

different batchings can be preconfigured and selected as necessary.<br />

• All the following functions in this function group, as well as the functions in the<br />

function groups VALVE PARAMETER (722) and SUPERVISION (724) are assigned to<br />

the batching specification selected here.<br />

• All the settings in the following functions <strong>of</strong> this function group are valid only for the<br />

batching specification selected in the function BATCH SELECTOR (7200). In other<br />

words, the entry or option is assigned to the batching specification currently selected<br />

(e.g. in the factory setting BATCH # 1).<br />

BATCH NAME<br />

(7201)<br />

Use this function to assign a specific name to the batching specification.<br />

User input:<br />

max. 8-character text, permissible: A-Z, 0-9<br />

Factory setting:<br />

Name <strong>of</strong> batching specification (depends on selection in the function BATCH SELECTOR<br />

(7200), e.g. “BATCH # 1”).<br />

! Note!<br />

Once an entry has been made (e.g. “BEER 33”), the batch name (BEER 33) appears in the<br />

home position when selecting the quantity and the name <strong>of</strong> the batching specification<br />

(e.g. “BATCH # 1”) no longer appears.<br />