3 Block MEASURED VARIABLES <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

Function description<br />

MEASURED VARIABLES MEASURING VALUES ADDITIONAL VALUES<br />

CORRECTED TARGET<br />

VOLUME FLOW<br />

(0024)<br />

! Note!<br />

This function is not available unless % MASS / % VOLUME was selected in the DENSITY<br />

FUNCTION function (7000), (see page 141).<br />

Use this function to display the currently measured corrected volume flow <strong>of</strong> the target<br />

fluid. Target fluid = carried material (e.g. lime powder).<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

CARRIER MASS FLOW<br />

(0025) ! Note!<br />

This function is not available unless one <strong>of</strong> the following was selected:<br />

• in the function DENSITY FUNCTION (7000), see page 141:<br />

– % MASS / % VOLUME<br />

– FLEXIBLE and in the function MODE (7010), see page 144, the selection<br />

% MASS 2D or % MASS 3D<br />

Use this function to display the currently measured mass flow <strong>of</strong> the carrier fluid.<br />

Carrier fluid = transporting liquid (e.g. water).<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

% CARRIER MASS FLOW<br />

(0026) ! Note!<br />

This function is not available unless one <strong>of</strong> the following was selected:<br />

• in the function DENSITY FUNCTION (7000), see page 141:<br />

– % MASS / % VOLUME<br />

– FLEXIBLE and in the function MODE (7010), see page 144, the selection<br />

% MASS 2D or % MASS 3D<br />

Use this function to display the currently measured mass flow <strong>of</strong> the carrier fluid as a %<br />

(<strong>of</strong> the overall mass flow). Carrier fluid = transporting liquid (e.g. water).<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

CARRIER VOLUME<br />

FLOW<br />

(0027)<br />

! Note!<br />

This function is not available unless one <strong>of</strong> the following was selected:<br />

• in the function DENSITY FUNCTION (7000), see page 141:<br />

– % MASS / % VOLUME<br />

– FLEXIBLE and in the function MODE (7010), see page 144, the selection<br />

% VOLUME 2D or % VOLUME 3D<br />

Use this function to display the currently measured volume flow <strong>of</strong> the carrier fluid.<br />

Carrier fluid = transporting liquid (e.g. water).<br />

Display:<br />

5-digit floating-point number, including unit and sign<br />

Page 14 • MN0M023<br />