9 Block BASIC FUNCTION <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

Function description<br />

BASIC FUNCTION PROCESS PARAMETER REFERENCE PARAMETER<br />

VALUE REFERENCE<br />

TEMPERATURE<br />

(6464)<br />

! Note!<br />

This function is not available unless the CALCULATED REFERENCE DENSITY setting<br />

was selected in the CORRECTED VOLUME CALCULATION function (6460).<br />

Entering the reference temperature for calculating the corrected volume flow, the<br />

corrected volume and the reference density.<br />

User input:<br />

5-digit floating-point number<br />

Factory setting:<br />

20.000 °C<br />

The reference density is calculated as follows:<br />

N = · (1 + t + t 2 ) ; where t = t - t N<br />

N = Reference density<br />

currently measured fluid density (measuring value <strong>Promass</strong>)<br />

t = Actual measured temperature <strong>of</strong> fluid (measuring value <strong>Promass</strong>)<br />

t N = Reference temperature for calculating the reference<br />

density (e.g. 20 °C)<br />

= Volumetric expansion coefficient <strong>of</strong> the fluid,<br />

Unit = [1/K]; K = Kelvin<br />

= Square volumetric expansion coefficient <strong>of</strong> the fluid, unit = [1/K 2 ]<br />

Page 128 • MN0M023<br />

Issue/Rev. 0.2 (12/12)