Proline Promass 83E/F/O Description of Device Functions - FMC ...
Proline Promass 83E/F/O Description of Device Functions - FMC ...
Proline Promass 83E/F/O Description of Device Functions - FMC ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />
8 Block INPUTS<br />
8.2.2 Function group OPERATION<br />
INPUTS F STATUS INPUT FAA<br />
<br />
CURRENT INPUT FCA CONFIGURATION 520<br />
<br />
OPERATION 524<br />
Function description<br />
INPUTS CURRENT INPUT OPERATION<br />
ACTUAL CURRENT<br />
INPUT<br />
(5240)<br />
SIMULATION<br />
CURRENT INPUT<br />
(5241)<br />
The actual value <strong>of</strong> the input current appears on the display.<br />
Display:<br />
0.0...25 mA<br />
Use this function to activate simulation <strong>of</strong> the current output.<br />
Options:<br />
OFF<br />
ON<br />
Factory setting:<br />
OFF<br />
! Note!<br />
• An active simulation is indicated by the<br />
“SIM. CURRENT 1” (# 661) notice message.<br />
• The value output for the simulation at the current input is defined in the function<br />
VALUE SIMULATION CURRENT INPUT (5242).<br />
• The measuring device remains fully operational during the simulation and the current<br />
measured values are output correctly via the other outputs and the display.<br />
" Caution!<br />
The setting is not saved if the power supply fails.<br />
VALUE SIMULATION<br />
CURRENT INPUT<br />
(5242)<br />
! Note!<br />
This function is only available if the function SIMULATION<br />
CURRENT INPUT (5241) is switched on.<br />
Use this function to specify a freely selectable value, e.g. 12 mA, which is to be simulated<br />
at the current input. This value is used to test downstream devices and the measuring<br />
device itself.<br />
User input:<br />
0.00...25.00 mA<br />
Factory setting:<br />
0.00 mA or 4 mA (depending on the setting in function 5201).<br />
" Caution!<br />
The setting is not saved if the power supply fails.<br />
Issue/Rev. 0.2 (12/12) MN0M023 • Page 117