7 Block OUTPUTS <strong>Device</strong> <strong>Functions</strong> <strong>Proline</strong> <strong>Promass</strong> 83<br />

Function description<br />

OUTPUTS RELAY OUTPUT (1...2) OPERATION<br />

VALUE SIMULATION<br />

SWITCH POINT<br />

(4742)<br />

! Note!<br />

The function is not visible unless the function SIMULATION SWITCH POINT (4741) is<br />

active (= ON).<br />

Use this function to define the status <strong>of</strong> the relay output during the simulation. This value<br />

is used to test downstream devices and the measuring device itself. Depending on the<br />

relay configuration (as make or break contact) the following selections are available.<br />

Options:<br />

Relay output configured as normally open (make) contact:<br />

MAKE CONTACT OPEN<br />

MAKE CONTACT CLOSED<br />

Relay output configured as normally closed (break) contact:<br />

BREAK CONTACT OPEN<br />

BREAK CONTACT CLOSED<br />

" Caution!<br />

The setting is not saved if the power supply fails.<br />