5. SHIPPING - START-UP<br />

5.3 Assembling <strong>the</strong> Machine<br />

5.3.1 The machine is shipped unassembled.<br />

1. Lay <strong>the</strong> frame gibs out correctly (back strip with <strong>the</strong> hose, <strong>the</strong> air socket directed towards <strong>the</strong> rear) on a suitable<br />

table or stand.<br />

2. Slide <strong>the</strong> rigid sled up, clamping flush left<br />

Necessary tool:<br />

Necessary accessory:<br />

hexagon socket screw key SW 4 mm<br />

hexagon socket screw key SW 5 mm<br />

premounted<br />

3. Slide <strong>the</strong> movable sled up - no clamping required.<br />

4. Fasten lateral gibs<br />

Necessary tool:<br />

Necessary accessory<br />

hexagon socket screw key SW 5 mm<br />

hexagon socket screw M6<br />

diameter 5 dowel pin<br />

5. Attach <strong>the</strong> ends of <strong>the</strong> hose to <strong>the</strong> air inlet socket.<br />

5.4 Installation at <strong>the</strong> Final Destination Site<br />

5.4.1 Fastening to <strong>the</strong> worktable with <strong>the</strong> angle bracket, which is included in <strong>the</strong> shipment<br />

5.4.2 Fix <strong>the</strong> foot pedal to <strong>the</strong> appropriate position on <strong>the</strong> floor<br />

5.5 Setting <strong>the</strong> ZMV-p<br />

No setting is necessary because <strong>the</strong> frame and profile are preset.<br />

5.6 Start-Up<br />

5.<strong>6.</strong>1 Pneumatic connection<br />

The ZMV-p is provided with a 2 meter long air hose with a diameter of 6/3“. A Euro-Quick coupling is mounted<br />

according to <strong>the</strong> system in <strong>the</strong> destination country.<br />

• Lift <strong>the</strong> setting button of <strong>the</strong> maintenance unit up and turn it counterclockwise.<br />

• Connect <strong>the</strong> pneumatic compressed air with a quick coupling or a stop valve with ventilation.<br />

• Caution: The machine operator must always be able to disconnect <strong>the</strong> machine from <strong>the</strong> compressed air system<br />

within a maximum distance of 3 meters.<br />

• Lift <strong>the</strong> setting button of <strong>the</strong> maintenance unit up and turn clockwise. The manometer (pressure gauge) reads<br />

5.5 - 6 bar ( 0.55 - 0.6 Mpa). Press <strong>the</strong> adjusting button down.<br />