12.11.2012 Views

YP-36/YC-13 Customer : Parts No.

YP-36/YC-13 Customer : Parts No.

YP-36/YC-13 Customer : Parts No.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

2<br />

3<br />

4<br />

5<br />

東莞永力電業有限公司<br />

東莞永力電業有限公司<br />

YUNG LI CO., LTD<br />

Da Pu Industrial Zone, Gang Zi, Changping Town,<br />

Dong Guan City, Guangdong 523571 China.P.R.C<br />

TEL:0769-3396797~8 FAX:0769-3396796<br />

E-mail: sales@yung-li.com<br />

Description : (SAA)<strong>YP</strong>-<strong>36</strong>/<strong>YC</strong>-<strong>13</strong><br />

<strong>Customer</strong> :<br />

<strong>Parts</strong> <strong>No</strong>. :<br />

Draw <strong>No</strong>. :<br />

YUNG LI<br />

REVISION RECORD<br />

CHECKED PREPARED BY<br />

CUSTOMER APPROVED


SPECIFICATION<br />

T<strong>YP</strong>E DESCRIPTION PART NO. PAGE<br />

<strong>YP</strong>-<strong>36</strong>/<strong>YC</strong>-<strong>13</strong> POWER SUPPLY CORD 1 of 5<br />

1. SCOPE:<br />

This specification applies to POWER SUPPLY CORDS which are in compliance<br />

With SAA standards AS 3112 with approval number as follow:<br />

2. Standard of applicable Type Max. voltages Max. current<br />

2.1 plug <strong>YP</strong>-<strong>36</strong> 250V 10A<br />

2.2 connector <strong>YC</strong>-<strong>13</strong> 250V 2.5A<br />

2.3 cord H03VVH2-F 2 x 0.75mm 2<br />

3. TEST CONDITION: This test and measurement, unless otherwise specified shall be carried out at a<br />

temperature of 15 0 C to 35 0 C, relative humidity of 25% to 85%, and atmospheric<br />

pressure of 86kpa to 106kpa.<br />

However, when any doubt arises on the judgement value under it the test and<br />

measurement shall be carried out at a temperature of 20±2 0 C, relative humidity<br />

of 60% to 70%, and atmospheric pressure of 86kpa to 106kpa.<br />

4.ELECTRICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

4-1 Dielectric<br />

Withstanding<br />

Voltage test<br />

4-2 Current and<br />

Polarity test<br />

(a) In this air (20±5 0 C)<br />

AC2000V is applied between a conductor<br />

and other conductor for 1 second.(Cut off current<br />

0.3mA).<br />

(b) Immersed in water(20±5 0 <strong>No</strong> breakage<br />

C)<br />

<strong>No</strong> breakage<br />

AC 1000V is applied between a conductor and<br />

other conductor for 1 minute<br />

<strong>No</strong> problem with<br />

Conductor


SPECIFICATION<br />

T<strong>YP</strong>E DESCRIPTION PART NO. PAGE<br />

<strong>YP</strong>-<strong>36</strong>/<strong>YC</strong>-<strong>13</strong> POWER SUPPLY CORD 2 of 5<br />

4. ELECTRICAL PERFORMANCE<br />

4.<br />

<strong>No</strong>. ITEM Test condition Requirement<br />

4-3<br />

Insulation<br />

resistance<br />

4-4 Conductor<br />

resistance<br />

5.MECHANICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

5-1 Tensile strength<br />

(initial sample)<br />

5-2 Deformation<br />

test<br />

(a) In the air (20 0 C)<br />

(b) In the air (60 0 C)<br />

insulation<br />

Exposure to 120±3 0 C atmosphere for 0.5H<br />

Weight 510g<br />

5-3 Aging test Exposure to 75±2℃, atmosphere for 168 hours<br />

under natural ventilation.<br />

5MΩ/ km MIN<br />

25.0Ω/ km MAX<br />

15LBS/2min<br />

The thickness of<br />

sample shall not<br />

decrease more<br />

than 50%<br />

<strong>No</strong> crack mucus<br />

mark wire exposure<br />

short and oppositive<br />

polarity.


SPECIFICATION<br />

T<strong>YP</strong>E DESCRIPTION PART NO. PAGE<br />

<strong>YP</strong>-<strong>36</strong>/<strong>YC</strong>-<strong>13</strong> POWER SUPPLY CORD 3 of 5<br />

5. MECHANICAL PERFORMANCE (CODE)<br />

NO. Item Test condition Requirement<br />

5-4 Input & output It is tested after taking the action of 10time<br />

Force to connector input & output.<br />

6. MECHANICAL PERFORMANCE<br />

Applied force is<br />

1~6kg<br />

NO. Item Test condition Requirement<br />

6-1 Pulling out<br />

force of conductor<br />

The connector between blade terminal and<br />

conductor shall not break under a lull force of<br />

20lbs for 1minute<br />

20LBS<br />

Blade can not<br />

fall down


SPECIFICATION<br />

T<strong>YP</strong>E DESCRIPTION PART NO. PAGE<br />

<strong>YP</strong>-<strong>36</strong>/<strong>YC</strong>-<strong>13</strong> POWER SUPPLY CORD 4 of 5<br />

6.MECHANICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

6-2 Pulling out force The attachment plug is supported on a horizontal The residual<br />

of blades steel plate with the blades down ward through a displacement of<br />

hole sufficiently large just to permit the blades to either blade must not<br />

pass through it a weight than exert 89N force for more than 2.4mm<br />

two minutes is to be supported by each blade in after 2 minutes of<br />

succession.<br />

load.<br />

6-3 Pulling out<br />

force of cord<br />

89N<br />

The joint in flexible cord is to be securely supportrated<br />

by a rigid flat mounted horizontally, a pull of<br />

<strong>13</strong>3.4N weight for one minute to the flexible cord<br />

<strong>13</strong>3.4N<br />

<strong>No</strong> looseness


SPECIFICATION<br />

T<strong>YP</strong>E DESCRIPTION PART NO. PAGE<br />

<strong>YP</strong>-<strong>36</strong>/<strong>YC</strong>-<strong>13</strong> POWER SUPPLY CORD 5 of 5<br />

6.MECHANICAL PERFORMANCE<br />

NO. Item Test condition Requirement<br />

6-4 Bending force The power supply cord division is fixing and load<br />

of 1000g is added to a tip of a cable. It is made to<br />

do 10000times bending on right and left each 45 0<br />

(bending speed 60 times/minute)<br />

45°<br />

1000g<br />

45°<br />

<strong>YC</strong>-<strong>13</strong><br />

Breaking rate is<br />

under 30%


Yung Li<br />

8/10/2004<br />

Edition<br />

A<br />

Marking:<br />

Style<br />

Size<br />

YUNG LI CO., LTD<br />

SPECIFICATION<br />

PVC FLEXIBLE CORDS<br />

H03VVH2-F 2 x 0.75mm 2<br />

Document <strong>No</strong><br />

Page<br />

1/2<br />

Size<br />

2 x 0.75mm<br />

Conductor Material<br />

Annealed Bare Copper<br />

Construction<br />

24 /∮0.20+0/-0.005<br />

Material<br />

PVC<br />

Minimum Average Thickness 0.50mm<br />

Insulation<br />

Minimum Thickness at any point 0.35mm<br />

Diameter<br />

Identification<br />

Core Twist<br />

2-Core<br />

Core Assembly Filler<br />

NA<br />

Assembly Pair<br />

NA<br />

Taping<br />

Mylar Foil<br />

NA<br />

Shielded A1-Mylar Foil<br />

NA<br />

Drain<br />

Material<br />

Construction<br />

NA<br />

NA<br />

Material<br />

PVC<br />

Minimum Average Thickness 0.60mm<br />

Jacket<br />

Minimum Thickness at any point 0.44mm<br />

Overall Diameter(Approx)<br />

3.4 ± 0.1/5.6±0.15<br />

Color<br />

Any Color<br />

2<br />

1. Standard: IEC 227<br />

2. Construction & Dimension<br />

Item Specification<br />

2.15 ± 0.10<br />

Blue,Brown<br />

2<br />

YUNG LI H03VVH2-F 2X0.75mm VDE NF-USE <strong>13</strong>47<br />

KEMA-KEUR<br />

IEMMEQU Q04083 A004049 227 IEC 52 RVV 300/300V KTL SU01027-4001<br />

N<br />

F<br />

CEBEC D FI<br />

+<br />

N S


Yung-Li<br />

8/10/2004<br />

Edition<br />

A<br />

Style<br />

Size<br />

4.Electrical & Physical Properties<br />

Rating Voltage<br />

Insulation Resistance<br />

Dielectric Strength<br />

Item<br />

YUNG LI CO., LTD<br />

SPECIFICATION<br />

PVC FLEXIBLE CORDS<br />

H03VVH2-F 2 x 0.75mm 2<br />

Spark Test 5KV<br />

Insulation<br />

Jacket<br />

Deformation Test<br />

Cold Bend Test<br />

Heat Shock Test<br />

Graph:<br />

Unaged<br />

Aged<br />

Loss of mass Test<br />

Unaged<br />

Aged<br />

Tensile Strength<br />

Elongation<br />

Tensile Strength<br />

Elongation<br />

70℃ 300/300V<br />

Specification<br />

0.011MΩ/Km 70℃ Min<br />

Document <strong>No</strong><br />

2/2<br />

AC 2.0 KV / 5 min <strong>No</strong> Brcak<br />

1.25Mpa Min 1.28kgf/mm 2<br />

150% Min<br />

Tensile Strength 1.25Mpa Min 1.28kgf/mm2<br />

Elongation 150% Min<br />

Min 75% (80℃x168hrs)<br />

Min 65% (80℃x168hrs)<br />

2.0mg/cm 2 (max)<br />

Tensile Strength Min 75% (80℃x168hrs)<br />

Elongation Min 65% (80℃x168hrs)<br />

Loss of mass Test 2.0mg/cm 2 (max)<br />

PVC JACKET(被覆)<br />

PVC INSULATION(絕緣)<br />

COPPER CONDUCTOR(導体)<br />

150mm, 70±2℃m X 1hr ≦ 50%<br />

-15℃ x 4hr <strong>No</strong> Crack<br />

150± 2℃ x 1hr <strong>No</strong> Crack<br />