16.01.2015 Views

MobileAccess2000 TSX Datasheet - Tessco

MobileAccess2000 TSX Datasheet - Tessco

MobileAccess2000 TSX Datasheet - Tessco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Datasheet</strong><br />

<strong>MobileAccess2000</strong> <strong>TSX</strong><br />

<strong>Datasheet</strong><br />

The <strong>MobileAccess2000</strong> platform provides carriergrade<br />

indoor coverage for a wide range of 2G, 3G,<br />

and 4G mobile voice and data services, over a<br />

single, broadband architecture.<br />

The MA2000 is the leading multi-operator, multiservice<br />

platform, which delivers multiple radio<br />

frequency (RF) services over one common and costeffective<br />

cabling and antenna infrastructure for a<br />

complete solution.<br />

Operator RF services are bi-directionally transmitted<br />

(Uplink/Downlink) between an operator’s capacity<br />

source (BTS/BDA) at the infrastructure head-end<br />

and then distributed to/from remote locations and<br />

multiple buildings, using low-loss fiber and coaxial<br />

cabling media.<br />

Other converged options include WMTS and the<br />

MA2000 system offers MIMO (multi-input/multioutput)<br />

capabilities.<br />

Head-End:<br />

System Controller<br />

Base Unit<br />

Features & Benefits:<br />

Multi-Operator Optimized Platform:<br />

Designed to accommodate multiple operator<br />

requirements separately, yet cost-effectively<br />

across one common infrastructure. Preassembled<br />

modular service packs improve<br />

neutral host ROI for the 1 st carrier in, as well as<br />

the 2 nd and 3 rd .<br />

Multi-Service Platform: Accommodates<br />

virtually any mix of wireless services, eliminating<br />

the need for separate cabled networks for each.<br />

Services include: GSM, CELL, PCS, iDEN, LMR,<br />

SMR, Public Safety, AWS, 700 MHz LTE, Paging,<br />

UMTS, DCS, WMTS, and more.<br />

Modular Design: The MA2000 enables<br />

seamless service upgrades with the addition of a<br />

conditioning card in the head-end and selfcontained<br />

service packs in IDF/Telco/IT closets<br />

at remote-ends.<br />

Scalable Media and MIMO Upgrades:<br />

Additional services leverage the existing coaxial<br />

cabling and antenna grid without disrupting work<br />

spaces or existing services. Fiber links extend a<br />

single capacity source across multiple buildings<br />

in campus environments. Multi-MIMO upgrades<br />

are simple with modular elements.<br />

Carrier-Grade Management: Built-in signal<br />

grooming and an Element Management System<br />

(EMS) offer end-to-end visibility and proactive<br />

alarming, ideal for large scale, multi-operator<br />

environments.<br />

Remote-End:<br />

MA2000 <strong>TSX</strong><br />

Service Combiner Unit<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 1


MA2000 System Architecture<br />

The <strong>MobileAccess2000</strong> solution is comprised of the following elements. Third-party equipment is sold separately (i.e.<br />

cabling, antennas).<br />

Head-End Equipment<br />

Radio Interface Unit (RIU): The RIU conditions the RF Downlink (DL) signals from an operator’s signal source<br />

(BTS: base-transceiver stations or BDA: bi-directional amplifiers) located inside the building. The RIU then custom<br />

tunes incoming signals in order to ensure a constant level of RF before signals are passed to/from the Base Unit<br />

(BU). RF Uplink (UL) signals from subscribers’ phones are received from the BU and transported back to the<br />

operator’s signal source (BTS or BDA) and to the operator’s macro network outdoors.<br />

Base Unit (BU): The BU converts RF Downlink (DL) signals received from the RIU into an optical signal. This<br />

optical signal is then transported over single or multi-mode fiber optic cabling (SMF/MMF) to/from the MA2000<br />

<strong>TSX</strong> units, which are housed inside of IDF/Telco/IT closets at the remote-end locations, for distribution throughout<br />

the facility. Uplink (UL) signals from subscribers’ phones are received from the antennas and sent back to the <strong>TSX</strong><br />

units through the fiber connection to the head-end, where they are converted back from RF optical to RF electrical<br />

before being passed on to the RIU.<br />

System Controller: The system controller enables centralized remote management and control of all MA2000<br />

elements.<br />

Remote-End Equipment<br />

Tri-Service Package (<strong>TSX</strong>): The Tri-Service Package (<strong>TSX</strong>) delivers coverage for three RF services over a<br />

common fiber/coax antenna infrastructure. The output of multiple <strong>TSX</strong> units can be combined to provide a full<br />

multi-service solution over a common fiber/coax antenna infrastructure. The <strong>TSX</strong> comes pre-packaged with<br />

applicable filters and other required accessories to simplify the ability to order, service, and install this solution.<br />

The sub-components of the <strong>TSX</strong> are as follows:<br />

Remote Hub Unit (RHU): The RHU is a services-specific module that performs RF optical to RF electrical<br />

conversion on signals received from the BU. Signals are automatically filtered and amplified for transport over<br />

broadband coax cable to a passive antenna. Uplink (UL) signals from the antennas are then converted to<br />

optical signals before being transmitted back to the BU. Each pre-configured RHU supports up to two<br />

services.<br />

Add-On Module (AO): The AO is a single service module coupled with an RHU to deliver an additional, third<br />

service at a lower incremental cost. The AO receives RF signal from the RHU and amplifies it for transport<br />

across the broadband coax.<br />

Service Combiner Unit (SCU): The Service Combiner Unit is a passive module that combines and distributes<br />

the UL and DL signals from all the MA2000 <strong>TSX</strong> to the broadband antenna.<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 2


Figure 1: Example MA2000 System Architecture with <strong>TSX</strong><br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 3


Supported Services<br />

Low Band Services<br />

700 LTE<br />

700/800 Public Safety<br />

Frequency Range (MHz)<br />

Uplink (UL)<br />

698-716<br />

777-787<br />

793-805<br />

806-824<br />

Downlink (DL)<br />

728-757<br />

763-775<br />

851-869<br />

CELL 824-849 869-894<br />

SMR 800 (iDEN 800) 806-824 851-869<br />

SMR 900 (iDEN 900) 896-902 929-941<br />

High Band Services<br />

Frequency Range (MHz)<br />

Uplink (UL)<br />

Downlink (DL)<br />

PCS 1850-1915 1930-1995<br />

AWS 1710-1755 2110-2155<br />

RF Parameters per Service<br />

The RF Parameters listed in the table below are specific to the RHU subcomponent of the MA2000 <strong>TSX</strong> solution. They<br />

take into account the transmission of the RF through the four-port Service Combiner Unit (P/N SCU-4).<br />

MA2000 <strong>TSX</strong> RHU RF Parameters<br />

MA2000 RHU<br />

RF Parameter<br />

Max Output Power per<br />

Antenna Port 4<br />

1 (Composite)<br />

700 / 800<br />

Public<br />

Safety<br />

CELL<br />

TDMA /<br />

CDMA /<br />

WCDMA<br />

SMR 800<br />

iDEN 800<br />

Sprint<br />

SMR 900<br />

iDEN 900<br />

Sprint<br />

PCS<br />

GSM /<br />

TDMA<br />

CDMA /<br />

WCDMA<br />

DL UL DL UL DL UL DL UL DL UL DL UL DL UL<br />

14 16 14 10 14 10<br />

2 Carriers 11 13 11 7 11 7 20<br />

4 Carriers 8 10 8 4 8 4 17<br />

8 Carriers 5 7 5 1 5 1 14<br />

12 Carriers 2 5 3 -1 3 -1 11<br />

Mean Gain(dB) 1, 4 14 3 16 7 14 7 10 7 14 7 10 7 9<br />

Pin (dBm) 1 0 0 0 0 0 0 20 3<br />

Input IP3 (dBm) AGC OFF Min -6 -5 -5 -5 -5 -5 0<br />

Input IP3 (dBm) AGC ON Min 6 5 5 5 5 5 -6<br />

SFDR 2 (dB) 71 72 72 71 71 3<br />

Max Intermod Distortion (dBm) -13* -13 -13 -13 -13 64<br />

Max Nf (dB) 20 20 20 20 20 20 -13*<br />

Gain Flatness/Ripple (dB) 3 +/-2.0<br />

* WCDMA compiles with 3GPP TS 25.106 V5.0.0 (2002-03) table 9.4 spectrum emission mask.<br />

1 Factory set mean gain BU-RHU without RIU. May be field adjusted using controller system.<br />

2 SFDR for CDMA services is calculated in 100KB/sec.<br />

3 Gain Flatness/Ripple is specified for the non-duplexed port of the system.<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 4


RF Parameters per Service<br />

The RF Parameters listed in the table below are specific to the AO subcomponent of the MA2000 <strong>TSX</strong> solution. They take<br />

into account the transmission of the RF through the four-port Service Combiner Unit (P/N SCU-4).<br />

MA2000 <strong>TSX</strong> Add-On RF Parameters<br />

MA2000 Add-On<br />

RF Parameters<br />

LTE 700 MHz<br />

PCS<br />

CDMA / WCDMA<br />

PCS<br />

GSM / TDMA<br />

AWS<br />

CDMA / WCDMA<br />

DL UL DL UL DL UL DL UL<br />

Max Output Power per Antenna Port<br />

1 (Composite) 21 20 21 21<br />

2 Carriers 18 17 18 18<br />

4 Carriers 15 14 15 15<br />

8 Carriers 11 12 12<br />

12 Carriers 9 10 10<br />

Mean Gain(dB) 1 21 20 3 20 3 21 3<br />

Pin (dBm) 1 0 0 1 0<br />

Max. Intermodulation Distortion (dBm) ** -13* -13 *<br />

Input IP3 (dBm) -10 -7 -7 -7<br />

SFDR (dBm) 2 55 66 64 66<br />

Max NF (dB) 20 18 18 18<br />

Gain Flatness/Ripple (dB) 3 +/-1.0 4 +/-2.0<br />

* WCDMA compiles with 3GPP TS 25.106 V5.0.0 (2002-03) table 9.4 spectrum emission mask.<br />

** Out of band and spurious emissions compliant to FCC.<br />

1 Factory set mean gain BU-RHU without RIU. May be field adjusted using controller system.<br />

2 SFDR for CDMA services is calculated in 100KB/sec.<br />

3 Gain Flatness/Ripple is specified for the non-duplexed port of the system.<br />

4 Gain Flatness/Ripple at any block of the spectrum.<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 5


System Specifications<br />

Absolute Maximum Rating<br />

Total Input RF Power to BU<br />

Total Input RF Power to RHU<br />

Power Supply<br />

Optical Specifications<br />

Optical Output Power<br />

Max. Optical Budget<br />

Optical Loss per Mated-pair<br />

Connectors<br />

10dBm<br />

20dBm out-of-band; -10dBm in-band<br />

60VDC<br />


System Component Specifications<br />

Tri-Service Package (<strong>TSX</strong>)<br />

The <strong>TSX</strong> comes fully assembled with an RHU, AO, and applicable filters and accessories. The specifications below reflect<br />

this. As a reference, details of the subcomponents (RHU an AO) are also provided.<br />

Supported Services<br />

Ports<br />

Power<br />

Three services per <strong>TSX</strong> (1 RHU + 1 AO). Refer to the <strong>TSX</strong> model<br />

for specific services support.<br />

To Service Combiner Unit: 50Ω QMA cables<br />

Local Power: 100-240VAC (Integrated AC/DC converter)<br />

Remote Power: 25 to 48VDC<br />

Power Consumption: 85W<br />

Physical Characteristics Mounting: 19” Rack mountable (Rack mountable brackets pre-connected)<br />

Dimensions: 51.4cm x 35.0cm x 17.7cm (20.24” x 13.78” x 6.97”)<br />

Weight: 19Kg (42 lb)<br />

Remote Hub Unit<br />

Supported Services<br />

Ports<br />

Power<br />

Two services per RHU<br />

Optical Port to BU: One SC/APC<br />

Input Power: 20 to 48V DC<br />

Power Consumption: 29W<br />

Physical Characteristics Dimensions: 27.9cm x 22.0cm x 4.5cm (10.98” x 8.66” x 1.75”)<br />

Weight: 2.8Kg (6.2 lb)<br />

Add-On<br />

Supported Services<br />

Ports<br />

Input Power<br />

Single service per AO<br />

To RHU: Two pre-connected SMA 50Ω connectors<br />

Input Power: 25 to 48V DC<br />

Power Consumption: 50W<br />

Physical Characteristics Dimensions: 27.9cm x 22.0cm x 6.9cm (10.98” x 8.66” x 2.71”)<br />

Weight: 2.8Kg (6.2 lb)<br />

Service Combiner Unit (4 Port)<br />

Supported Services<br />

High band (1710 MHz - 2155 MHz) and low band (698 MHz – 941 MHz) RF services<br />

Ports<br />

To MA2000 <strong>TSX</strong>: 8 QMA 50Ω connectors (Terminate if unused)<br />

To Antennas: 4 N-Type 50Ω connectors (Terminate if unused)<br />

Physical Characteristics Dimensions: 16.6cm x 8.0cm x 3.5cm (6.5” x 3.15” x 1.38”)<br />

Comes with bracket that allows it to be mounted directly on top of a MA2000 <strong>TSX</strong><br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 7


Multimode Fiber Qualifications<br />

50/125 or 62.5/125um complying with ANSI/TIA/EIA-568-B series, EN50173-1 or ISO/IEC 11801, may be used up to 300<br />

meters in length assuming the following qualifications:<br />

Both the Base Unit and Remote Hub Unit must be multimode capable.<br />

All fiber in a given length of fiber must be of the same core diameter.<br />

All bulkhead adapters must be Single-mode SC/APC (Green) adapters.<br />

All terminations, cross connections, or patches must be direct fusion splice or MobileAccess specified patchcords<br />

listed below.<br />

900 Micron Patchcord for Splicing, 2 Meters, 2xSC/APC<br />

62.5/125/900 Diamond p/n ENC/1045341 FiberNext p/n OEM-629002-MAN<br />

50/125/900 Diamond p/n ENC/1045340 FiberNext p/n OEM-509002-MAN<br />

Zipcord Patchcord, 4xSC/APC, 50/125/900/2000/4500 Micron<br />

1Meter Diamond p/n ENC/1045342 FiberNext p/n OEM-50ZIP1-MAN<br />

3 Meter Diamond p/n ENC/1045343 FiberNext p/n OEM-50ZIP3-MAN<br />

Zipcord Patchcord, 4xSC/APC, 62.5/125/900/2000/4500 Micron<br />

1Meter Diamond p/n ENC/1045344 FiberNext p/n OEM-62ZIP1-MAN<br />

3 Meter Diamond p/n ENC/1045345 FiberNext p/n OEM-62ZIP3-MAN<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 8


Ordering Information:<br />

Radio Interface Unit<br />

Part Number<br />

RIU-IM<br />

RIU-BTSC-700LTE<br />

RIU-BTSC-PS700<br />

RIU-BDAC-PS700<br />

RIU-BTSC-CELL<br />

RIU-BDAC-CELL<br />

RIU-BTSC-IDEN<br />

RIU-BDAC-IDEN<br />

RIU-BTSC-PCS<br />

RIU-BDAC-PCS<br />

RIU-BTSC-G -PCS<br />

RIU-BDAC-G-PCS<br />

RIU-BTSC-SMR<br />

RIU-BDAC-SMR<br />

RIU-BTSC-GSM<br />

RIU-BDAC-GSM<br />

RIU-BTSC-GSM-O<br />

RIU-BDAC-GSM-O<br />

RIU-BTSC-DCS<br />

RIU-BDAC-DCS<br />

RIU-BTSC-UMTS<br />

RIU-BTSC-AWS<br />

RIU-BDAC-AWS<br />

RIU-L-IDEN-SMR-G-PCS1<br />

RIU-L-CELL-PCS1<br />

Description<br />

Radio Interface Unit, Support for 1-3 Conditioners<br />

700 LTE Conditioner, 0 to +40dBm Input Range<br />

Public Safety 700 MHz Conditioner, +10 to +36dBm Input Range<br />

Public Safety 700 MHz Conditioner, -16 to +36dBm Input Range<br />

Cellular Conditioner, +10 to +36dBm Input Range<br />

Cellular Conditioner, -16 to +10dBm Input Range<br />

iDEN/SMR800 Conditioner, +10 to +36dBm Input Range<br />

iDEN/SMR800 Conditioner, -16 to +10dBm Input Range<br />

PCS Conditioner, +10 to +36dBm Input Range<br />

PCS Conditioner, -16 to +10dBm Input Range<br />

PCS Conditioner w/ G-Block Support, +10 to +36dBm Input Range<br />

PCS Conditioner w/ G-Block Support, -16 to +10dBm Input Range<br />

SMR900/Paging Conditioner, +10 to +36dBm Input Range<br />

SMR900/Paging Conditioner, -16 to +10dBm Input Range<br />

GSM 900 MHz Conditioner, +10 to +36dBm Input Range<br />

GSM 900 MHz Conditioner, -16 to +10dBm Input Range<br />

GSM 900 MHz Conditioner for Orange, +10 to +36dBm Input Range<br />

GSM 900 MHz Conditioner for Orange, -16 to +10dBm Input Range<br />

DCS 1800 MHz Conditioner, +10 to +36dBm Input Range<br />

DCS 1800 MHz Conditioner, -16 to +10dBm Input Range<br />

UMTS 2100 MHz Conditioner, +10 to +36dBm Input Range<br />

AWS Conditioner, +10 to +36dBm Input Range<br />

AWS Conditioner, -16 to +10dBm Input Range<br />

RIU Lite for iDEN 800,SMR 900, PCS1900 w/G-Block, Support 1BU8, -16 to +10dBm Input<br />

Range<br />

RIU Lite Cellular 800, PCS 1900, -16 to +10dBm Input Range<br />

Base Units<br />

Part Number<br />

WB-B8U<br />

WBM-B8U<br />

WB-B4U<br />

WBM-B4U<br />

Description<br />

Wide Band Base 8 Unit Supporting 8 RHUs<br />

Wide Band Base 8 Unit Supporting 8 RHUs over MMF<br />

Wide Band Base 4 Unit Supporting 4 RHUs<br />

Wide Band Base 4 Unit Supporting 4 RHUs over MMF<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 9


Ordering Information:<br />

MA2000 <strong>TSX</strong><br />

Service Supported Part Number Description<br />

700/800 MHz<br />

Public Safety<br />

2000-P71S80-A-TC<br />

2000M-P71S80-A-TC<br />

MA2000 <strong>TSX</strong> dual-service 700/800 MHz Public Safety.<br />

MA2000 <strong>TSX</strong> dual-service 700/800 MHz Public Safety with MMF.<br />

700/800 MHz<br />

Public Safety/AWS<br />

CELL/PCS<br />

2000-P71S80A17-A-TC<br />

2000M-P71S80A17-A-TC<br />

2000-C85P19-A-TC<br />

2000M-C85P19-A-TC<br />

MA2000 <strong>TSX</strong> tri-service 700/800 MHz Public Safety and AWS.<br />

MA2000 <strong>TSX</strong> tri-service 700/800 MHz Public Safety and AWS with<br />

MMF.<br />

MA2000 <strong>TSX</strong> dual-service CELL/PCS.<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS with MMF.<br />

CELL/PCS/700LTE<br />

CELL/PCS/AWS<br />

IDEN/SMR<br />

IDEN/SMR/PCS<br />

IDEN/SMR/AWS<br />

2000-C85P19L70-A-TC<br />

2000-C85P19L70-A-TC-F<br />

2000M-C85P19L70-A-TC<br />

2000M-C85P19L70-A-TC-F<br />

2000-C85P19A17-A-TC<br />

2000M-C85P19A17-A-TC<br />

2000-S80S90-A-TC<br />

2000M-S80S90-A-TC<br />

2000-S80S90P19-A-TC<br />

2000M-S80S90P19-A-TC<br />

2000-S80S90A17-A-TC<br />

2000M-S80S90A17-A-TC<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS and 700 MHz LTE.<br />

- Additional filter (P/N 700LTE-PS-FILTER) ordered separately.<br />

Required if 700/800 MHz Public Safety coexists across same<br />

infrastructure.<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS and 700 MHz LTE with filter to<br />

support 700/800 MHz Public Safety coexistence.<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS and 700 MHz LTE with filter to<br />

support 700/800 MHz Public Safety coexistence with MMF.<br />

- Additional filter (P/N 700LTE-PS-FILTER) ordered separately.<br />

Required if 700/800 MHz Public Safety coexists across same<br />

infrastructure.<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS and 700 MHz LTE with filter to<br />

support 700/800 MHz Public Safety coexistence with filter to support<br />

700/800 MHz Public Safety coexistence and MMF.<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS and AWS.<br />

MA2000 <strong>TSX</strong> tri-service CELL/PCS and AWS with MMF.<br />

MA2000 <strong>TSX</strong> dual-service 800/900 MHz SMR. Supports 700 MHz LTE<br />

and 700/800 MHz Public Safety coexistence.<br />

MA2000 <strong>TSX</strong> dual-service 800/900 MHz SMR with MMF. Supports 700<br />

MHz LTE and 700/800 MHz Public Safety coexistence.<br />

MA2000 <strong>TSX</strong> tri-service 800/900 MHz SMR and PCS. Supports 700<br />

MHz LTE and 700/800 MHz Public Safety coexistence.<br />

MA2000 <strong>TSX</strong> tri-service 800/900 MHz SMR and PCS with MMF.<br />

Supports 700 MHz LTE and 700/800 MHz Public Safety coexistence.<br />

MA2000 <strong>TSX</strong> tri-service 800/900 MHz SMR and AWS. Supports 700<br />

MHz LTE and 700/800 MHz Public Safety coexistence.<br />

MA2000 <strong>TSX</strong> tri-service 800/900 MHz SMR and PCS with MMF.<br />

Supports 700 MHz LTE and 700/800 MHz Public Safety coexistence.<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 10


Ordering Information:<br />

Service Combiner Unit<br />

SCU-4<br />

Part Number<br />

Description<br />

Service Combiner Unit supporting 4 Antenna output ports, 4 Low Band services input ports and 4<br />

High Band services input ports. To be used with the MA2000 <strong>TSX</strong> solution.<br />

Element Management Components<br />

Part Number<br />

Description<br />

410 Network Controller with Serial Interface (Dial-up)<br />

SC-450<br />

MobileAccess System Controller<br />

Accessories<br />

Optional Filters<br />

Part Number<br />

700LTE-PS-FILTER<br />

Power Supply<br />

Part Number<br />

LPS-48V-66W<br />

LPS-48V-100W<br />

AK-PWR-CORD-EU<br />

AK-PWR-CORD-UK<br />

Description<br />

Cavity filter for the 700LTE Add-On when 700LTE service coexists with 700/800 Public Safety<br />

service across the same set of coax. This filter is already included with the MA2000 <strong>TSX</strong><br />

CELL/PCS/700LTE part numbers with a “-F” suffix.<br />

Local AC/DC Converter 66W<br />

Local AC/DC Converter 100W<br />

Description<br />

AC Power Cord for 66W and 100W Power Supplies, European Connector<br />

AC Power Cord for 66W and 100W Power Supplies, UK Connector<br />

www.tessco.com | 800.472.7373<br />

MobileAccess<br />

8391 Old Courthouse Road, Suite 300, Vienna, VA 22182<br />

Tel: +1(866)436-9266, +1(703)848-0200 TAC: +1(800)787-1266, Fax: +1(703)848-0280<br />

www.mobileaccess.com<br />

DS_MA2000_CE0002301_Rev A00_12AUG10.docx 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!