Operating Manual Electronic Floor Scale M30610 - Dencor
Operating Manual Electronic Floor Scale M30610 - Dencor Operating Manual Electronic Floor Scale M30610 - Dencor
Operating Manual Electronic Floor Scale M30610 ADE GmbH & Co. Hammer Steindamm 27 – 29 D – 22089 Hamburg Germany +49(40)432776-0 Fax +49(40)432776-10 E-mail: info@ade-hamburg.de
- Page 2 and 3: Contents Contents .................
- Page 4 and 5: Installation and use of scale Your
- Page 6 and 7: Definition and use of BMI (Body Mas
- Page 8: CE marking and Declaration of Confo
<strong>Operating</strong> <strong>Manual</strong><br />
<strong>Electronic</strong> <strong>Floor</strong> <strong>Scale</strong> <strong>M30610</strong><br />
ADE GmbH & Co.<br />
Hammer Steindamm 27 – 29<br />
D – 22089 Hamburg<br />
Germany<br />
+49(40)432776-0<br />
Fax +49(40)432776-10<br />
E-mail: info@ade-hamburg.de
Contents<br />
Contents .................................................................................................................................................. 1<br />
Components and Features...................................................................................................................... 2<br />
Display symbols ..................................................................................................................... 2<br />
Installation and use of scale .................................................................................................................... 3<br />
Check carton contents ...........................................................................................................3<br />
Before weighing ..................................................................................................................... 3<br />
Weighing.................................................................................................................................................. 4<br />
To take the weight.................................................................................................................. 4<br />
Change unit function .............................................................................................................. 4<br />
Set zero.................................................................................................................................. 4<br />
Tare function .......................................................................................................................... 4<br />
Definition and use of BMI (Body Mass Index)........................................................................ 5<br />
Evaluation of the Body Mass Index........................................................................................ 5<br />
HOLD function........................................................................................................................ 5<br />
Cleaning and Maintenance...................................................................................................................... 6<br />
Cleaning ................................................................................................................................. 6<br />
Safety Check.......................................................................................................................... 6<br />
Warranty – Liability................................................................................................................. 6<br />
CE marking and Declaration of Conformity............................................................................................. 7<br />
Declaration of CE Conformity................................................................................................. 7<br />
Technical data ......................................................................................................................................... 7<br />
1 050100-Rev000-<strong>M30610</strong>
Components and Features<br />
Tare key<br />
Key to turn scale ON, OFF and ZERO setting<br />
Key to switch between weighing mode (kg or lb) and key-in height for BMI function<br />
HOLD key and BMI (Body Mass Index) selecting key<br />
Display symbols<br />
ο<br />
ο <br />
NET <br />
HOLD <br />
Weighing result is displayed most accurately<br />
<strong>Scale</strong> is under automatic zero setting<br />
<strong>Scale</strong> is indicating NET weight<br />
HOLD function is active<br />
050100-Rev000-<strong>M30610</strong> 2
Installation and use of scale<br />
Your ADE <strong>Electronic</strong> <strong>Floor</strong> <strong>Scale</strong> is a quality product. In order to achieve best possible results please<br />
read and follow strictly the instructions of this <strong>Operating</strong> <strong>Manual</strong>:<br />
Check carton contents<br />
- <strong>Floor</strong> <strong>Scale</strong> and cable display<br />
- Mains adapter<br />
- <strong>Operating</strong> <strong>Manual</strong><br />
Before weighing<br />
Power supply of the scale: By mains adapter (12V 300 mA) and rechargeable batteries<br />
- The display is already equipped with rechargeable batteries.<br />
- To charge the power-pack for the first time please use the mains adapter.<br />
- Complete first charging needs 24 hrs.<br />
- Place the scale in its working area.<br />
- Make sure to place the scale on an even ground.<br />
- The scale is now ready for use.<br />
Caution:<br />
Please operate the scale only with the original ADE mains adapter that has been delivered.<br />
- Always fit the adapter to the scale BEFORE connecting to an electrical outlet<br />
- Disconnect from the electrical outlet BEFORE disconnecting the adapter from the scale.<br />
- The mains adapter is not waterproof. Therefore make sure NOT to use the scale where water<br />
can penetrate.<br />
- In case the mains adapter became wet or show visible damages the scale can no longer be<br />
operated by using this mains adapter. In this case please contact your local dealer or service<br />
partner.<br />
3 050100-Rev000-<strong>M30610</strong>
Weighing<br />
To take the weight<br />
- Press key ON to start the scale. `8888´will appear on the display which is an automatic<br />
function test and zero setting. When `0.0´appears you are in the kg weighing mode. In addition<br />
display will show the symbol `o´ to confirm stability of the zero setting.<br />
- The scale may now be used.<br />
- Step on the platform and stand still.<br />
- After display is showing your weight and symbol `o´ appeared the most accurate result has<br />
been reached.<br />
- To turn off the scale press key OFF for minimum 3 seconds. This is essential if scale is used<br />
on batteries. Using the scale on mains it may remain permanently switched on or can be shut<br />
off manually by pressing key.<br />
Change unit function<br />
You may select the weight unit between kg and lb. Coming from the factory the scale is switched to kg<br />
mode. To change into lb mode press UNIT/HEIGHT key.<br />
Caution<br />
- Please check weighing mode after switching to get proper result.<br />
Set zero<br />
You may set any displayed weighing result back to zero `0.0´by pressing the ZERO key. The<br />
advantage is to weigh shoes or dress separately.<br />
- Place objects on the scale.<br />
- Press ZERO key.<br />
- Unload the scale.<br />
- The weight displayed before is showing a negative value and will be deducted automatically<br />
during the next weighing procedure.<br />
- The negative value will not be stored.<br />
Tare function<br />
The tare function (also known as mother & child function) allows to store a fixed weight that will be<br />
deducted each weighing procedure unless deleted or replaced by another.<br />
- Take weight as described before and store the result by pressing the TARE key.<br />
- The scale is now in NET weighing mode which is also indicated on the display.<br />
- If for example you stored the weight of the mother or nurse, she can step now on the scale<br />
with the baby in her arms.<br />
- The weight displayed is the weight of the baby.<br />
- The scale identified the added weight. You may now use the scale for as many weighing<br />
procedures and the stored value will always be deducted.<br />
050100-Rev000-<strong>M30610</strong> 4
Definition and use of BMI (Body Mass Index)<br />
The Body Mass Index is the ratio between height and weight squared. The BMI is meanwhile<br />
accepted world wide – also by WHO (World Health Organization) - helping to evaluate the state of<br />
nutrition and with that also the state of health of a person. The result is a tolerance value.<br />
- Press the HOLD/BMI key for at least 3 seconds.<br />
- By doing that you selected the storage mode for your own height in cm. You will also find the<br />
word `HIGHT´ on the display.<br />
- Once entered the mode you find a given value that you will probably have to change.<br />
- The first digit (normally a 1) is blinking. Change indication if necessary by pressing the<br />
UNIT/HEIGHT key by using the numeric key stored (0-9).<br />
- Press the HOLD/BMI key again and you will get to the next digit.<br />
- Repeat the procedure until your exact height is shown on the display.<br />
- Press TARE key for confirmation and you will get back into the normal weighing mode.<br />
- Press again HOLD/BMI key to enter the BMI mode.<br />
- Step on the platform.<br />
- The blinking display offers you both – your weight and your BMI.<br />
- To deactivate the BMI mode press again HOLD/BMI key.<br />
Evaluation of the Body Mass Index<br />
BMI below 18<br />
• The patient is not showing enough weight. Control nutrition to put on weight.<br />
BMI between 18 and 20<br />
• The patient is slightly under weighed. If he feels well there is no need for a change.<br />
BMI between 20 and 25<br />
• The patient is in the range of normal weight.<br />
BMI between 25 and 30<br />
• The patient is slightly overweighed. A reduction of weight is indicated or, is necessary if the<br />
state of health is already affected (e.g. diabetes, high end blood pressure, heart diseases).<br />
BMI over 30<br />
• Reduction of weight is imperative. Also to visit a doctor is highly recommended.<br />
HOLD function<br />
By using the HOLD function the identified weight might be stored and is shown on the display even if<br />
you stepped already off the scale. The advantage is to take care of the patient first and then take note<br />
of the weight.<br />
- Press HOLD/BMI key while scale is under load.<br />
- The display shows a blinking arrow symbol next to the HOLD symbol.<br />
- Once the scale is loaded with more than 3 kg the blinking stops.<br />
- The weight displayed will now also show after unloading of the platform.<br />
- To deactivate the Hold function press again HOLD/BMI key.<br />
- If you are in Hold mode you might also change over to the Tare function by pressing the<br />
TARE key. which means both functions might be used simultaneously.<br />
5 050100-Rev000-<strong>M30610</strong>
Cleaning and Maintenance<br />
Cleaning<br />
Before cleaning make sure the scale has been disconnected from the socket.<br />
For cleaning just use a damp cloth or common disinfection fluids.<br />
Do not use any aggressive cleaning fluids.<br />
Make sure no water or cleaning fluids is penetrating the scale.<br />
Your ADE scale is equipped with a mains adapter and rechargeable batteries.<br />
If the display shows the symbol `Low´ the power pack needs to be recharged by using the adapter.<br />
Safety Check<br />
Do NOT use the scale<br />
• If the mains adapter shows visible damages.<br />
• if the mains adapter is not working properly any more<br />
• After long storage in humid places<br />
Please contact your dealer or service partner in those cases.<br />
Storage and Transport<br />
Please keep all original parts and pieces for an eventual sending back of the scale<br />
in order to avoid any possible damage during transport which automatically leads to non warranty.<br />
Disconnect all cables before transport and avoid unnecessary damages.<br />
Warranty – Liability<br />
ADE will repair or replace this product within a period of 2 years from date of delivery applying to<br />
defects occurred due to poor material or workmanship (presentation of invoice is necessary). All<br />
moveable parts – batteries, cables, mains units, rechargeable batteries etc. – are excluded. Warranty<br />
does not include natural wear, damages caused by incorrect or negligent handling, overuse or<br />
unsuitable or improper storage. The cost of transport will be borne by the customer should the<br />
equipment be located anywhere other then the customer’s premises. In the event of transport<br />
damage, claims under warranty can be accepted subject to using the complete original packaging and<br />
the equipment secured the way it was packed and secured originally. All the packaging should<br />
therefore be retained.<br />
Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively<br />
by ADE to do so.<br />
Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer<br />
service and spare parts.<br />
050100-Rev000-<strong>M30610</strong> 6
CE marking and Declaration of Conformity<br />
ADE products are manufactured as per the standards applicable of the actual European norms and<br />
directives to produce and offer world-wide products at the latest technical standard and with a long<br />
lifetime.<br />
Declaration of CE Conformity<br />
This product corresponds to the valid EC Directive 89/336/EEC for electromagnetic compatibility.<br />
Products carrying this sign correspond to the standards of<br />
• Directive 73/23 EEC(for low voltage)<br />
Technical data<br />
Max. Capacity:<br />
Graduation:<br />
Weighing range:<br />
Display:<br />
Dimensions:<br />
Power supply:<br />
Zero setting:<br />
Working temperature:<br />
Weight:<br />
200 kg / 440 lbs<br />
100 g / 0,2 lb<br />
1 kg – 200 kg / 2 lbs – 440 lbs<br />
easy to read 25 mm LCD Display<br />
310 x 50 x 300 mm<br />
Mains and rechargeable batteries<br />
Automatic<br />
5 to +35 degrees Celsius<br />
abt. 18 kg<br />
Supplier:<br />
ADE GmbH & Co.<br />
Hammer Steindamm 27 – 29<br />
D – 22089 Hamburg<br />
Germany<br />
7 050100-Rev000-<strong>M30610</strong>