Troubleshooting Guide<br />

PROBLEM POSSIBLE CAUSE SOLUTION<br />

Cannot initiate start sequence<br />

• Air pressure switch has not<br />

made contact<br />

Check air-pressure switch<br />

adjustment<br />

Check air filter<br />

Check blower rotation<br />

Check outlet pressure from<br />

blower<br />

• High gas pressure switch has<br />

tripped<br />

• Low gas pressure switch has<br />

tripped<br />

• Malfunction of flame monitoring<br />

control system such as<br />

shorted out flame sensor or<br />

electrical noise in the sensor line.<br />

• Purge cycle not completed<br />

• Main power is off<br />

• No power to control unit<br />

Check incoming gas pressure<br />

Adjust gas pressure if<br />

necessary<br />

Check pressure switch setting<br />

and operation<br />

Check incoming gas pressure<br />

Adjust gas pressure if<br />

necessary<br />

Check pressure switch<br />

setting and operation<br />

Have a qualified electrician<br />

investigate and rectify.<br />

Check flame monitoring control<br />

system or purge timer.<br />

Make sure power is on to control<br />

system<br />

Call qualified electrician to<br />

investigate.<br />

30 <strong>Eclipse</strong> <strong>ThermJet</strong> v2, Installation Guide No. 205, 3/5/07