26.07.2012 Views

New Portable Plasmacluster Ion Generator

New Portable Plasmacluster Ion Generator

New Portable Plasmacluster Ion Generator

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>New</strong> <strong>Portable</strong> <strong>Plasmacluster</strong> <strong>Ion</strong> <strong>Generator</strong><br />

<strong>Plasmacluster</strong><br />

Technology You Can<br />

Take Anywhere<br />

<strong>Portable</strong> <strong>Plasmacluster</strong><br />

<strong>Ion</strong> <strong>Generator</strong><br />

IG-CM1<br />

<strong>Plasmacluster</strong> is a registered<br />

trademark or trademark of<br />

Sharp Corporation.<br />

<strong>Plasmacluster</strong>—Only from Sharp<br />

-B Black -W White<br />

-P Pink<br />

The number in this technology mark represents an approximation of the number of ions discharged into the air per cubic centimeter (cm 3 )<br />

measured with the unit’s stand fully opened and, using a reference point approximately 80 cm from the unit’s discharge vent, at distances<br />

20 cm above, 10 cm below, and 20 cm horizontally to the left and right centered on that point.<br />

<strong>Plasmacluster</strong>’s skin beautifying effects<br />

Actual effectiveness will vary according to the season, room conditions (temperature, humidity, airflow, etc.), usage duration, and person.<br />

<strong>Plasmacluster</strong>’s<br />

skin moisturizing<br />

mechanism<br />

The water molecules that surround<br />

<strong>Plasmacluster</strong> <strong>Ion</strong>s adhere to<br />

the skin, forming a “water molecule<br />

coating.” This keeps the stratum<br />

corneum (skin surface) moist.<br />

Moisture<br />

evaporates<br />

No ions<br />

Skin surface (stratum corneum)<br />

dries out.<br />

<strong>Portable</strong> <strong>Plasmacluster</strong><br />

<strong>Ion</strong> <strong>Generator</strong><br />

<strong>Plasmacluster</strong><br />

<strong>Ion</strong>s<br />

Moisture on the surface (stratum corneum)<br />

is preserved.<br />

Tested by: The Research Institute of Electrical Communication at Tohoku University<br />

Test results: Confirmed that <strong>Plasmacluster</strong> <strong>Ion</strong>s allowed the formation of a water molecule<br />

coating on the skins surface.<br />

Skin Moisture Skin Elasticity Skin Texture<br />

<strong>Plasmacluster</strong> technology is effective in suppressing the action of airborne viruses, and in decomposing and eliminating airborne allergens<br />

such as dust mite feces and dried, dead mite body parts. However, it cannot create a completely sterile environment, and Sharp does not<br />

guarantee its ability to prevent microbial infection.<br />

Stratum<br />

corneum<br />

With ions<br />

IG-CM1<br />

Water<br />

molecule<br />

coating


H + H + H +<br />

O2 −<br />

O2 −<br />

O2 −<br />

Credible academics and professionals have validated<br />

the effects of <strong>Plasmacluster</strong> technology.<br />

■<strong>Plasmacluster</strong>’s suppression mechanism (the images below are illustrations)<br />

Breaks down and removes<br />

airborne allergens<br />

such as dust mite feces and dead dustmites<br />

■Removal of dust mite allergens in airborne<br />

house dust<br />

●Tested by: Hiroshima University Graduate<br />

School of Advanced Sciences of Matter<br />

●Test method: The effect of airbone dust mite<br />

allergens in an uncleaned room (about 30 m 3 in<br />

volume) was measured in an actual home by<br />

the ELISA (Enzyme-Linked ImmunoSorbant<br />

Assay) method. Sharp converted the results<br />

and calculated the average value.<br />

(<strong>Plasmacluster</strong> <strong>Ion</strong> density: 3,000 ions/cm 3 )<br />

●Test results: After four weeks, <strong>Plasmacluster</strong><br />

<strong>Ion</strong>s removed over 99.9% of airborne allergens.<br />

Suppresses the effects<br />

of airborne viruses<br />

This was tested in an enclosed, 1-m 3 box for 10 minutes.<br />

It has not been tested in an open environment.<br />

■Suppression of airborne virus effectiveness<br />

●Tested by: Retroscreen Virology Ltd., UK<br />

●Test method: Viruses were suspended in the<br />

air inside a 1-m3 box, and the percentage of<br />

airborne viruses removed was measured.<br />

●Test results: (1) In about 10 minutes,<br />

<strong>Plasmacluster</strong> <strong>Ion</strong> density of 7,000 ions/cm3 removed 99.0% of airborne viruses. (2) In about<br />

10 minutes, density of 50,000 ions/cm3 removed 99.9% of airborne viruses.* 1<br />

OH Radical<br />

H<br />

Hydrogen<br />

Protein<br />

Breaks down and<br />

removes airborne mold<br />

■Removal of airborne mold<br />

●Tested by: Ishikawa Health Service<br />

Association, Japan<br />

●Test method: <strong>Plasmacluster</strong> <strong>Ion</strong>s were emitted<br />

into an experimental chamber about 30 m3 in<br />

volume, and airborne mold was measured with<br />

an air sampler. Sharp has graphed the results<br />

using approximate figures. (<strong>Plasmacluster</strong> <strong>Ion</strong><br />

density: 3,000 ions/cm3 )<br />

●Test results: In about 195 minutes,<br />

<strong>Plasmacluster</strong> <strong>Ion</strong>s removed 99.0% of airborne<br />

mold.<br />

The following condition can ensure an ion<br />

density nearly the same as the<br />

<strong>Plasmacluster</strong> <strong>Ion</strong> density in the 1 m 3 box<br />

used in the virus proof test.<br />

*Actual numbers of ions and<br />

disinfecting/purifying effectiveness will vary<br />

according to the room conditions (air<br />

conditioning, ventilayion, airflow, product<br />

location, etc.) and the operation method<br />

(direction ions are blowing, whether the<br />

stand is fully open or not, etc.). Test results<br />

do not guarantee similar results in an<br />

actual space.<br />

H2O<br />

Suppresses the activity<br />

of airborne microbes<br />

■Suppression of airborne microbe activity<br />

●Tested by: Dr. Melvin First, Harvard School of<br />

Public Health, USA<br />

●Test method: Microbe was inserted into the air<br />

of an approx. 40 m3 experimental chamber. The<br />

remaining microbe was collected to measure<br />

the removal rate. (<strong>Plasmacluster</strong> <strong>Ion</strong> density:<br />

4,700 ions/cm3 )<br />

●Test results: In about 38 minutes,<br />

<strong>Plasmacluster</strong> <strong>Ion</strong>s removed 99.0% of airborne<br />

microbe.<br />

Suppresses the proliferation<br />

of adhering mold<br />

■Suppression and removal of adhering mold<br />

●Tested by: Japan Food Research Laboratories<br />

●Test results: No. 09010744001-01 on October<br />

27, 2009<br />

●Test method: Sharp generated ions in a<br />

2.6-m3 space, grew mold on PVC plates for 5<br />

days, and entrusted them to a test institution.<br />

Mold growth areas were compared as directed<br />

by JIS Z2911. (<strong>Plasmacluster</strong> <strong>Ion</strong> density:<br />

25,000 ions/cm3 )<br />

●Test results: Suppressed proliferation of<br />

adhering mold after five days.<br />

Removes static electricity<br />

■Removal of static electricity<br />

●Tested by: Sharp Corporation<br />

●Test method: An acrylic plate was placed<br />

inside a 1-m3 airtight box. <strong>Plasmacluster</strong> <strong>Ion</strong>s<br />

were generated inside the box and the amount<br />

of static electricity was measured.<br />

(<strong>Plasmacluster</strong> <strong>Ion</strong> density: 25,000 ions/cm3 )<br />

●Test results: After approx. 7.5 minutes the<br />

initial static potential of 4.0 kV had dropped to<br />

1.0 kV.<br />

Breaks down and<br />

removes clinging odors<br />

■Removal of cigarette smoke odor from cloth<br />

●Tested by: Japan Spinners Inspecting<br />

Foundation<br />

●Test method: To evaluate deodorizing<br />

effectiveness, the six-level odor intensity<br />

indication method was used on a cloth swatch<br />

impregnated with cigarette smoke odor<br />

components. Sharp has converted and<br />

calculated the results. (<strong>Plasmacluster</strong> <strong>Ion</strong><br />

density: 20,000 ions/cm3 )<br />

●Test results: Odor became unnoticeable after<br />

approx. one hour.<br />

*1 For this product, the ion density measured with the unit’s stand fully open, using a reference point approximately 80 cm from the unit’s discharge vent, at distances 20 cm above, 10 cm below, and 20 cm horizontally to the left and right centered on that point.<br />

Battery life under<br />

continuous use:<br />

approx.<br />

8 hours<br />

Thanks to its lithium-ion battery, users can take it anywhere and use it anytime.<br />

The IG-CM1 can be used generously<br />

whether eating lunch outdoors or<br />

commuting by train, even in places with no<br />

power.<br />

●Full battery charge time: approx. 4 hours 45 minutes<br />

Users can charge the device by connecting the<br />

power cord to an AC outlet, as well as by<br />

connecting to a computer via USB cable.* 2<br />

In places where an outlet is hard to reach, such as<br />

an office desk, the IG-CM1 is very convenient.<br />

*2 The unit-charging accessory can be connected to a computer via USB cable, but please check the specifications of your computer in advance. In addition, we cannot guarantee that computer operation failure or other troubles such as<br />

data loss due to this connection will not occur.<br />

■Specifications<br />

IG-CM1<br />

■Replacement <strong>Plasmacluster</strong> <strong>Ion</strong> generation unit<br />

AC adapter (100-240 V ) / lithium-ion rechargeable battery<br />

Approx. 0.8 m<br />

With AC adapter: 3.4 (max) / with USB connection: 450 mA (max)<br />

29<br />

*3 The recommended distance refers to the maximum distance that allowed for the unit to blow enough ions through the air to achieve the measured ion density of 25,000 ions/cm3 when the unit is running with the stand fully open. When the stand is<br />

closed the distance is approximately 0.3 m.<br />

*4 When operated with the stand fully open.<br />

*4<br />

Model<br />

Power supply<br />

Recommended distance<br />

57 x 27.5 x 124 (W x D x H)<br />

Approx. 0.15 (power cord not included)<br />

AC adapter, USB cable, cap cover<br />

Approx. 1.8<br />

*3<br />

Compatible device<br />

IG-CM1<br />

Model<br />

IZ-CCM1E<br />

Power consumption (W)<br />

Contents<br />

<strong>Plasmacluster</strong> <strong>Ion</strong> generation unit (1 set)<br />

Operating noise level (dB)<br />

Outer dimensions (mm)<br />

■Battery for <strong>Plasmacluster</strong> <strong>Ion</strong> generation unit<br />

Weight (kg)<br />

Compatible device<br />

IG-CM1<br />

Accessory items<br />

Model<br />

IZ-BTCM1E<br />

Power cord (m)<br />

Contents<br />

1 lithium-ion battery<br />

●Actual numbers of ions will vary according to the room conditions and operation method.<br />

Distributed by:<br />

●<strong>Plasmacluster</strong> technology is effective in suppressing the action of<br />

airborne viruses, and in decomposing and eliminating airborne<br />

allergens such as dust mite feces and dried, dead mite body parts.<br />

However, it cannot create a completely sterile environment, and Sharp<br />

does not guarantee its ability to prevent microbial infection.<br />

●Actual numbers of ions and disinfecting/purifying effectiveness will<br />

vary according to the room conditions (air conditioning, ventilation,<br />

airflow, product location, etc.) and the operation method.<br />

©SHARP CORP. (MAR. 2011)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!