1-PSA-INOX STAR Bedien engl. M12_M16_M20 - 2012-06 ... - RUD
1-PSA-INOX STAR Bedien engl. M12_M16_M20 - 2012-06 ... - RUD
1-PSA-INOX STAR Bedien engl. M12_M16_M20 - 2012-06 ... - RUD
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>RUD</strong>-Art.-Nr.: 7997882-EN / 03.013<br />
> <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <<br />
EN<br />
Safety instructions<br />
This safety instruction/declaration of the manufacturer has to be<br />
kept on file for the whole lifetime of the production.<br />
Translation of the Original instructions<br />
<strong>PSA</strong> – Fall Protection<br />
Anchorage Point<br />
<strong>RUD</strong> Ketten<br />
Rieger & Dietz GmbH u. Co. KG<br />
73428 Aalen<br />
Tel. +49 7361 504-1351-1370-1262<br />
Fax +49 7361 504-1460<br />
info@rud.com<br />
www.rud.com<br />
Eye bolt made out of stainless<br />
Duplex-steel<br />
<strong>M12</strong> (1 Pers.)<br />
<strong>M16</strong> (2 Pers.)<br />
<strong>M20</strong> (2 Pers.)<br />
Implemented, harmonized standard: EN 795<br />
Testing regulation: EN 795 1996/A1:2001,<br />
EN 50308 2004 Abs. 4.5,<br />
OSHA 1926.502 (d)(15)<br />
Notifying department:<br />
FA <strong>PSA</strong> Test- and<br />
Certification department<br />
of BG - PRÜFZERT<br />
Zwengenberger Straße 68<br />
42781 Haan<br />
Identification No: 0299<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
1
Before every use, please read the Safety<br />
Instruction of the <strong>PSA</strong>-Fall protection<br />
anchorage point carefully and make sure<br />
that you understand all substance.<br />
Improper use ore care of this eyebolt can<br />
result in bodily injury or property damage<br />
and eliminates any warranty!<br />
1 Application and warning information<br />
WARNING<br />
Improper assembled or damaged fall<br />
protection anchorage points and inappropriate<br />
use can result in deadly injury or lead<br />
to heavy injuries when load drops.<br />
Inspect fall protection anchorage points<br />
before each use carefully!<br />
• <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> must only be used<br />
by competent and trained people with adequate<br />
knowledge, and outside Germany the corresponding<br />
country specific requirements must be<br />
utilised.<br />
• The user of the <strong>PSA</strong>-Fall protection anchorage point<br />
must be in good health to use this equipment. The<br />
hereby necessary certification can f.e. be verified<br />
by a G41-checkup.<br />
• The <strong>PSA</strong> anchorage points must only be loaded<br />
with the stated number of persons.<br />
• To enable safety and appropriate information for<br />
all users in case of a resell to an other country, the<br />
reseller must provide the user instruction,<br />
maintenance instruction for the regular inspection<br />
and the repairing in the country specific language.<br />
2 Intended use of <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong> eyebolt can be used as<br />
anchor point, for fall protection harnesses. This anchor<br />
point (subsequently named <strong>PSA</strong> anchorage point) can<br />
also be attached permanent to a building, so that a<br />
fall protection harness can be hooked in.<br />
Only for the rescue out of highs and lows emergencydown<br />
devices can be additionally attached (see BGR<br />
199 Chapter 3.1.3.6 <strong>PSA</strong> anchorage points).<br />
The <strong>PSA</strong>-<strong>INOX</strong>-Star <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> eye bolt is<br />
designed for pivoting movements under load as they<br />
may occur at a fall.<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> must not be used<br />
when load swivels, because the <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
could turn loose.<br />
Observe the following WLL<br />
- <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>: max 1 Person permitted<br />
- <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M16</strong> and <strong>M20</strong>: max 2 Persons<br />
permitted<br />
In consequence of the assembly method this product<br />
fulfills the requirements as described in DIN EN 795<br />
paragraph 4.3 “special requirements for anchorage<br />
points“:<br />
2.1 Grade A1 (chapter 4.3.1 acc. to DIN EN 795)<br />
permanent installed <strong>PSA</strong> anchor points<br />
Grade A1 is fulfilled when the assembly is done in the<br />
following way:<br />
The <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> must be bolt,<br />
into the by the designed threaded hole, by using a<br />
suitable torque wrench. Therefore necessary moment<br />
of force and bolting torque can be taken out of the<br />
chart No. 1 page 4. In addition to that a liquid securing<br />
glue f.e. Loctite or WEICONLOCK (see manufactures<br />
instructions) must be used.<br />
The assembly of the <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong><br />
must be carried out in a way that the disassembly can<br />
only be done with a suitable tool.<br />
2.2 Grade B (chapter 4.3.1 acc. to DIN EN 795)<br />
temporary installed <strong>PSA</strong> anchor points<br />
Grade B is fulfilled when the assembly is done in the<br />
following way:<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong> must be bolt into the by<br />
design specified thread by using either the provide<br />
key or with a suitable hexagon key applied with a normal<br />
hand force of 50 daN.<br />
Both assembly methods require that the ring is free<br />
moveable (swivels 360° around the bolt axis, see<br />
chapter 4.2 hints for the assembly - Point 6).<br />
Acc. to DIN EN 795 Point 4.2, chapter 4 “General<br />
requirements for anchor points“ <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
<strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> can be used in an outdoor environment,<br />
because the corrosion resistance corresponds at least<br />
to the 4.4 values of EN 362:1992.<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> must only be used<br />
in the here described applications.<br />
2 <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong>
3 Material properties<br />
The utilised stainless Duplex-steel 1.4462 for the body<br />
and the bolt has a good resistance against wear and<br />
local corrosion like pitting, crevice corrosion and stress<br />
corrosion cracking in sea water and high chloride and<br />
H2S containing media.<br />
This steel is very common in the construction industry,<br />
chemical industry, oil industry, food industry (only limited<br />
resistance against lactic acid), in the machine<br />
engineering for example, as REA-components and<br />
transport boxes, in desalting plants at OFF-Shore<br />
areas like shipbuilding.<br />
The material can also be utilised in the nuclear industry<br />
as far as nuclear technical requirements or object<br />
specifications do allow the usage (according to VdTÜV<br />
418).<br />
HINT<br />
The material must not be used in the<br />
following areas:<br />
Load bearing parts in indoor swimming pool<br />
atmospheres, which are neither permanent<br />
rinsed with water nor cleaned, if their failure<br />
could cause serious personal injury.<br />
For example when used as connecting<br />
element for a suspended ceiling, pendents<br />
or loudspeakers or for the fixation of water<br />
slides or any other construction elements<br />
(read ISER-Merkblatt 831).<br />
4 Installation information<br />
4.1 General information<br />
• Capability of temperature usage:<br />
The stainless steel <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<br />
<strong>M20</strong> can be used in the temperature range between<br />
-40°C up to 280°C (according to VdTÜV 418).<br />
• <strong>RUD</strong> lifting points must not be used under chemical<br />
influences such as acids, alkaline solutions and<br />
vapours. Please observe chapter 2, Intended use<br />
of <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong>.<br />
• A plan must exist to accomplish rescue actions,<br />
including all kinds of possible emergencies<br />
occurring with the work.<br />
• If the <strong>PSA</strong>-Fall protection anchorage point is used<br />
in mobile applications, it must be handed out to the<br />
user personally.<br />
• Modifications or repairing on the <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
<strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> must be carried out by the<br />
manufacturer only.<br />
• Store fall protection eyebolt at dry and non corrosive<br />
environment only.<br />
Correct maintenance and storage are important for<br />
the safety of the worker.<br />
Marking of the <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong><br />
Front Reverse<br />
EN-Standard<br />
Manufacturer<br />
Type-denomination<br />
Traceability code<br />
CE-Marking<br />
Wear<br />
markings<br />
Year of<br />
production<br />
Size of thread<br />
<strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong><br />
No. of load<br />
bearing persons<br />
<strong>M12</strong>: 1 Pers.<br />
<strong>M16</strong>: 2 Pers.<br />
<strong>M20</strong>: 2 Pers.<br />
Hint for user´s<br />
instruction<br />
The markings are according to DIN EN 365 „Personal fall protection gear“<br />
– general requirements for user instructions and marking<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
3
4.2 Assembly information<br />
1. The material construction to which the lifting point<br />
will be attached should be of adequate strength to<br />
withstand forces during lifting without deformation<br />
(certificate of static forces).<br />
Employer´s insurance association recommends the<br />
following minimum engagement length for the bolts:<br />
- 1 x M, in steel (min. grade S235JR (1.0037))<br />
- 1,5 x M, in grey cast iron (f.e. GG 25)<br />
- 2 x M, in aluminium alloys<br />
- 2,5 x M, for light metals of low strength<br />
M = size of thread, f.e. <strong>M20</strong> (means 20 mm thread<br />
diameter)<br />
When lifting light metals, nonferrous metals and<br />
grey cast iron or other materials the thread has to<br />
be chosen in such a way that the WLL of the thread<br />
corresponds to the requirements of the corresponding<br />
base material.<br />
HINT<br />
<strong>RUD</strong>-<strong>PSA</strong> anchor points are standard wise<br />
supplied with a thread lengths of 1,5 x M.<br />
Make sure that the tapped hole is providing<br />
enough depth (see also chapter 4.2 Hints<br />
for the assembly – point 5).<br />
2. The bolting location for the eyebolt should be<br />
marked with paint.<br />
3. The <strong>PSA</strong> anchor point should be installed as follows:<br />
- configuration above user (does not exclude an<br />
other assembly position, but reduces the risk<br />
of tripping)<br />
- the coupling element must be free moveable,<br />
- the coupling element must not be loaded over<br />
edges<br />
4. Make sure that a plane bolting surface is provided<br />
(Ø E, see chart 2). Maximum countersink of the<br />
threaded hole = Nominal diameter of thread.<br />
5. Drill the tapped blind holes deep enough so that<br />
the shoulder of the <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<br />
<strong>M20</strong> bolt sits properly on the plane surface. At<br />
through holes please consider also DIN EN 20273<br />
middle<br />
6. <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong> must be adjustable<br />
trough 360° when tightened:<br />
- For a temporary assembly, hand tightening with<br />
an allen key is sufficient.<br />
- If the <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> shall be installed<br />
permanently, a torque of 25 Nm (+/- 10 %)<br />
must be applied, plus securing with threadlocker<br />
has to be done.<br />
It is possible to receive a socket wrench for the<br />
usage of a torque:<br />
Type <strong>PSA</strong>-<strong>INOX</strong> tightening Ref-No.<br />
torque of key<br />
<strong>PSA</strong>-<strong>INOX</strong> <strong>M12</strong> 25 Nm 7997750<br />
<strong>PSA</strong>-<strong>INOX</strong> <strong>M16</strong> 60 Nm 7997751<br />
<strong>PSA</strong>-<strong>INOX</strong> <strong>M20</strong> 115 Nm 7997752<br />
HINT<br />
Shock loading or vibrations can cause<br />
unintentional dismantling. To avoid this use<br />
liquid thread locker such as Loctite or<br />
WEICONLOCK (depending on the application,<br />
please pay attention to the manufacturer’s<br />
instruction).<br />
Attention: Ring Body has to be free<br />
rotatable.<br />
7. A competent person must check the lingering<br />
suitability of the <strong>PSA</strong>-fall protection anchor point<br />
after the installation is carried out (according to the<br />
general plant safety requirements § 2 - chapter 4).<br />
See also chapter 5, Inspection criteria.<br />
4.3 User information<br />
• Inspect <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> eyebolt regularly before<br />
each usage in regard of tightening, corrosion, wear,<br />
deformation etc. (see chapter 5 Inspection criteria).<br />
WARNING<br />
Wrong assembled or damaged <strong>PSA</strong> anchor<br />
point as well as incorrect usage may result<br />
in serious or deadly injuries.<br />
<strong>PSA</strong> anchor point must be in general<br />
inspected before each usage.<br />
• If a safe usage is doubtable or if the lifting mean<br />
has been stressed by a dropped load, for safety<br />
reasons the usage must be withdraw.<br />
A competent person must decide whether the lifting<br />
mean can be used further on.<br />
• The <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong> has to be<br />
adjustable through 360° when fitted and with key<br />
disengaged. Adjust to direction of pull before<br />
attaching of the coupling element.<br />
HINT<br />
Attention: <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>/<strong>M16</strong>/<strong>M20</strong><br />
eyebolts are not suited for turning under<br />
load!<br />
• When composing harness equipment to a disposal<br />
system make sure that they are supposed to be<br />
put together and that the coupling element is<br />
compatible with the fall protection device.<br />
• Care should be taken when selecting components<br />
of equipment to avoid any risk of injury to persons<br />
or damage of property. The safe function of a<br />
component or a compromised equipment must not<br />
be effected.<br />
• Eliminate any damage of the <strong>PSA</strong>-Fall protection<br />
anchorage point for example caused by loading on<br />
sharp edges.<br />
• The assembly of a <strong>PSA</strong> anchor point to a coupling<br />
element must be done by using coupling elements<br />
according to EN 362 (Grade B and M), which have<br />
to free moveable to all sides. Any other grades are<br />
prohibited. Exception: Grade T is allowed, depending<br />
on the shape.<br />
Chart 1<br />
4 <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong>
Squeezing, tripping, shear and joint locations must<br />
be avoided. The coupling element must not be<br />
kinking when loaded.<br />
• Karabiner hooks according to DIN 5290 are<br />
prohibited.<br />
• For a body harness (belt type) in a fall protection<br />
system only harness belts according to EN 362<br />
must be used.<br />
• For the worker’s safety it is very decisive that before<br />
each usage of the harness system clearance underneath<br />
the worker is assured. In case of a fall,<br />
touching ground or obstacle is avoided.<br />
• Hook coupling element of the selected harness<br />
system into the eye of the <strong>PSA</strong>-Fall protection<br />
anchorage point and lock the coupling accordingly.<br />
• Improper use of the lifting mean cause limitations<br />
in regard of the usage period. The system must be<br />
inspected and controlled according to chapter 5 of<br />
the Inspection criteria.<br />
• In addition to that please observe user instruction<br />
of all other components also.<br />
4.4 Hints for the regular inspection<br />
In time periodes complying to the need or usage a<br />
technical expert should control at least once a year<br />
the appropriateness of the anchor point. This<br />
inspection must also be done after each event of<br />
damage or special incident.<br />
5 Inspection criteria<br />
Observe and control the following points before each<br />
usage in regular periods, after assembly and after<br />
special incidents (see judgement of hazard, resp. note<br />
admitted technical rules):<br />
• Bolt tightening (torque)<br />
• Completeness of the lifting point<br />
• Complete, readability of the Working Load Limit<br />
(WLL) as well as existing sign of manufacturer<br />
• Deformation on load bearing parts like basic body<br />
and bolt<br />
• Mechanical damages like notches, especially when<br />
located in areas of tensile stress<br />
• strong corrosion<br />
• Reduction of cross section caused by wear > 10 %<br />
• Cracks at load bearing parts<br />
• Function and damage of bolts and threads<br />
• Easy turning of the ring, free of jerk must be assured<br />
• The product identification at the <strong>PSA</strong> anchor point<br />
must be high visible and easy to read<br />
• Please fill out the documentation card carefully and<br />
save it to write down regular inspections and<br />
possible repairings.<br />
anchor<br />
point<br />
coupling<br />
element<br />
shock<br />
absorber<br />
disposal belt<br />
Drawing <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
Overview disposal system with shock absorber<br />
(source: BGR 198, 10/2004, page 7 picture 6)<br />
Type WLL Weight A B C D E G K L M N S Certification- Ident-No.<br />
No.<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>* 1 Pers. 0.19 kg 42 14 10 30 30 32 56 18 12 8 18 PS 09<strong>06</strong>0052 7997097<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M12</strong>* 1 Pers. 0.22 kg 42 14 10 30 30 32 56 50 12 8 18 PS 09<strong>06</strong>0052 7997820<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M16</strong>* 2 Pers. 0.31 kg 49 17 15 35 36 38 65 24 16 10 24 PS 09<strong>06</strong>0045 7996757<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M20</strong>* 2 Pers. 0.53 kg 57 19 17 40 43 47 74 30 20 12 27.5 PS 11<strong>06</strong>1008 7900921<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong> <strong>M20</strong>* 2 Pers. 0.6 kg 57 19 17 40 43 47 74 60 20 12 27.5 PS 11<strong>06</strong>1008 7901252<br />
Chart 2 * dimensions in mm Subject to technical alterations<br />
<strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong><br />
5
6 Inspection card<br />
Produkt:<br />
Type: Trade name: Individual No.:<br />
Manufacturer:<br />
Address:<br />
Year of production: Date of purchase: First usage:<br />
Sequences of regular inspections<br />
Inspection<br />
Repairing<br />
Date OK Detected fault<br />
Name and<br />
signature of<br />
technical expert<br />
Date of<br />
next<br />
regular<br />
inspection<br />
Before <strong>PSA</strong>-Fall protection anchorage points will be used, please read user<br />
instruction carefuly. Make sure that you understand all the substance.<br />
Non-observance of this instruction may cause serious personal injury and/or<br />
damage to property!<br />
6 <strong>PSA</strong>-<strong>INOX</strong>-<strong>STAR</strong>