14.01.2015 Views

KX-TDA100BX - Panasonic

KX-TDA100BX - Panasonic

KX-TDA100BX - Panasonic

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>KX</strong>-<strong>TDA100BX</strong><br />

4.3. SYSTEM CAPACITY<br />

4.3.1. Maximum Trunk and Extension Cards<br />

The following number of trunk and extension cards can be installed in the main unit (Hybrid IP-PBX) for expansion.<br />

Card Type<br />

<strong>KX</strong>-TDA100<br />

Trunk Card *1 4<br />

Extension Card 4<br />

Total 5<br />

*1 One T1, E1, PRI30 and PRI23 card counts as 2 cards.<br />

Note:<br />

· For each card, a maximum number that can be installed in the main unit (Hybrid IP-PBX) is listed in "Installation Manual".<br />

· Any card that exceeds the capacity of the main unit (Hybrid IP-PBX) will be ignored.<br />

· When the main unit (Hybrid IP-PBX) starts up with an invalid configuration mode, some cards will be ignored.<br />

4.3.2. Maximum Terminal Equipment<br />

The following number of terminal equipment can be supported by the main unit (Hybrid IP-PBX).<br />

Terminal Equipment Type<br />

<strong>KX</strong>-TDA100<br />

Telephone *1 64<br />

CS 16<br />

PS 128<br />

Voice Mail 2<br />

Doorphone 8<br />

Door Opener 8<br />

*1 When only T76xx series and T7560, T7565 DPTs and SLTs are connected. If other DPTs or APTs are connected, the<br />

maximum number will decrease as each of these units is counted as 4 sets of SLTs or DPTs (T76xx series and T7560, T7565).<br />

4.3.3. Power Supply Unit Selection<br />

Main unit (Hybrid IP-PBX) needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of<br />

"load figures" from the type and number of equipment to be connected, and determine the type of PSU that will be required.<br />

Load Figure Calculation<br />

Equipment Type<br />

Load Figure<br />

PT DPT (T76xx series and T7560, T7565) 1<br />

Other DPT/APT/DSS Console 4<br />

Extension Card *1 DHLC8 8<br />

SLC8 8<br />

SLC16 16<br />

MSLC16 16<br />

CS 4<br />

ISDN Extension 2<br />

Voice Mail 1<br />

*1 Only the extension cards that can support SLTs count for the load figures.<br />

PSU Capability<br />

Each PSU supports a different amount of load figures.<br />

*2 Available for the <strong>KX</strong>-TDA100 and <strong>KX</strong>-TDA200.<br />

PSU Type<br />

Maximum Load Figures<br />

PSU-S 64<br />

PSU-M *2 128<br />

7