14.01.2015 Views

KX-TDA100BX - Panasonic

KX-TDA100BX - Panasonic

KX-TDA100BX - Panasonic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>KX</strong>-<strong>TDA100BX</strong><br />

12.1.1.6. DSP DTMF Receiver Diagnosis<br />

Diagnose DTMF receiver of DSP in the Card to use DTMF generator of DSP<br />

DHLC DLC SLC8/L<br />

SLC8<br />

MSLC/<br />

SLC16<br />

CS-INF LCOT T1 E1 BRI PRI OPB3 E&M CTI-<br />

LINK<br />

Object of Card X X<br />

Time slot<br />

Primary circuit<br />

DSP ST loop back<br />

DSP digital loop back<br />

OK<br />

NG<br />

Diagnosis point<br />

Time slot test<br />

Primary circuit loop back test<br />

DSP ST point loop back test<br />

DSP digital point loop back test<br />

Diagnosis result<br />

DSP DTMF generator/receiver diagnosis OK<br />

DSP DTMF generator/receiver diagnosis NG<br />

12.1.1.7. Framer IC Alarm Signal Detection Diagnosis<br />

Diagnose the feature to detect the alarm signal of Framer IC is normal action.<br />

DHLC DLC SLC8/L<br />

SLC8<br />

MSLC/<br />

SLC16<br />

CS-INF LCOT T1 E1 BRI PRI OPB3 E&M CTI-<br />

LINK<br />

Object of Card X X X<br />

RAI<br />

AIS<br />

Primary circuit<br />

OK<br />

NG<br />

Diagnosis point<br />

Yellow alarm signal detection test<br />

Blue alarm signal detection test<br />

Primary circuit alarm signal detection test<br />

Diagnosis result<br />

Framer IC alarm signal detection diagnosis OK<br />

Framer IC alarm signal detection diagnosis NG<br />

12.1.1.8. Framer IC Error Detection Diagnosis<br />

Diagnose the feature to detect the alarm signal of Framer IC is normal action.<br />

DHLC DLC SLC8/L<br />

SLC8<br />

MSLC/<br />

SLC16<br />

CS-INF LCOT T1 E1 BRI PRI OPB3 E&M CTI-<br />

LINK<br />

Object of Card X X X<br />

Bipolar violation error<br />

CRC error<br />

Framing error<br />

Primary circuit<br />

OK<br />

NG<br />

Diagnosis point<br />

Bipolar violation error detection test<br />

CRC error detection test<br />

Framing error detection test<br />

Primary circuit error detection test<br />

Diagnosis result<br />

DSP DTMF generator/receiver diagnosis OK<br />

DSP DTMF generator/receiver diagnosis NG<br />

12.1.1.9. CS-INF Loop Back Diagnosis<br />

Diagnose by Loop back test to CS-INF<br />

Object of Card<br />

DHLC DLC SLC8/L<br />

SLC8<br />

MSLC/<br />

SLC16<br />

CS-INF LCOT T1 E1 BRI PRI OPB3 E&M CTI-<br />

LINK<br />

X<br />

Dch port xx<br />

Bch port xx<br />

DNIC analog<br />

DNIC digital<br />

OK<br />

NG<br />

CS-INF loop back diagnosis test channel<br />

D channel Port No. xx test<br />

B channel Port No. xx test<br />

Diagnosis point<br />

DNIC analog loop back test<br />

DNIC digital loop back test<br />

Diagnosis result<br />

CS-INF loop back diagnosis OK<br />

CS-INF loop back diagnosis NG<br />

57