14.01.2015 Views

KX-TDA100BX - Panasonic

KX-TDA100BX - Panasonic

KX-TDA100BX - Panasonic

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>KX</strong>-<strong>TDA100BX</strong><br />

11.4. ERROR LOG<br />

When a major system error occurs in the main unit (Hybrid IP-PBX), the ALARM indicator on the front of the cabinet turns on<br />

red, and the system logs the error information.<br />

11.4.1. Error Log Display Format<br />

Example: <strong>KX</strong>-TDA Maintenance Console<br />

Example: Station Message Detail Recording (SMDR)<br />

Description<br />

Item<br />

Description<br />

1 Date Date of the error detection<br />

2 Time Time of the error detection<br />

3 Level Major Alarm (MJ ALM):<br />

Errors that affect the whole system operation, or result in system failure<br />

Minor Alarm (MN ALM):<br />

Errors that affect certain part of system operation<br />

4 Error Code Three-digit error code<br />

5 Sub Code Five-digit sub code (XYYZZ)<br />

X: Cabinet number (1 to 4)<br />

YY: Slot number<br />

<strong>KX</strong>-TDA100: 00 to 06 (00: MPR slot; 01 to 05: Free slot; 06: Option slot)<br />

<strong>KX</strong>-TDA200: 00 to 11 (00: MPR slot; 01 to 10: Free slot; 11: Option slot)<br />

ZZ: Physical port number (01 to 16)<br />

For OPB3 card, sub slot number + port number will be displayed.<br />

Subslot1:11to14<br />

Subslot2:21to24<br />

Subslot3:31to34<br />

Note:<br />

When there is no parameter for slot and physical port number, YY and ZZ<br />

will be displayed as "00".<br />

Example: Sub code for MPR card = 10000<br />

6 Error Message Error description (maximum 36 characters)<br />