Operator's Manual High Pressure Breathing Air Compressors
Operator's Manual High Pressure Breathing Air Compressors
Operator's Manual High Pressure Breathing Air Compressors
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Operator’s <strong>Manual</strong><br />
10.4. TECHNICAL DATA<br />
10.4.1. Filter specifications P41/P61* filter system<br />
a. General<br />
Service pressure, standard 225/330 bar (3,200/4,500 psi)<br />
Service pressure, max. 350 bar (5,000 psi)<br />
Flow rate max. 450 l/min / max. 600 l/min*<br />
Regenerated volume of air, referenced to 1 bar abs,<br />
20°C, flow rate 200 l/min against p = 200 bar<br />
1923 m3 ; 1732 m3 with CO cartridge<br />
3139 m3 with CO cartridge<br />
Operating temperature range +5 ... +50°C (41 ... 122°F)<br />
Residual water contents