10.3. FILTER MAINTENANCE<br />
10.3.1. General instructions<br />
48<br />
Operator’s <strong>Manual</strong><br />
-- Depressurize system before starting any maintenance work. The filter section can be vented manually at venting valve with<br />
gauge. Wait untill the pressure on the gauge has dropped to zero, before opening pressure vessel.<br />
-- Dry inside of filter housing with a clean cloth and check for corrosion before installing new cartridge. Replace any defective parts.<br />
-- Lubricate threads and O--rings as well as threaded part of cartridge with white petrolatum (DAB 9) or Never--Seez White. Apply<br />
sparingly.<br />
-- Observe number of operating hours/no. of bottle fillings to ensure paying exact attention to the maintenace intervals.<br />
-- Leave cartridge in the filter as long as unit is out of service, so that humidity entering the system is absorbed.<br />
-- Change cartridge before reactivating a compressor unit which has been out of service for more than 6 months.<br />
-- Keep all condensate drain valves and shut--off valves closed. Keep a minimum pressure of approx. 50 to 80 bar (700 to 1,100<br />
psig) within the system to prevent moisture entering the compressor piping and filter system.<br />
10.3.2. Oil and water separator maintenance<br />
The sintered filter micro--cartridge requires periodic cleaning. See maintenance intervals.<br />
Removal of sintered filter element (Fig. 29 ):<br />
-- Remove tube connected to non--return valve (2).<br />
-- Screw off filter head (3) and remove.<br />
-- Unscrew micro--cartridge (1) from filter head (3).<br />
-- Remove centre--screw (4) to remove filter elements.<br />
-- Clean sintered filter elements using hot soapy water and blow dry with clean compressed air.<br />
Condensate drain<br />
The condensate produced by the re--cooling after the compression process has to be drained regularly by means of the condensate<br />
drain valve<br />
• before start--up of the compressor unit<br />
• during operation every 15 minutes, at high humidity every<br />
10 minutes.