6.5.1. Changing the lube oil for preserving<br />

34<br />

Operator’s <strong>Manual</strong><br />

-- After prolonged storage, the oil will age in the compressor and engine. It should be drained after 2 years at the latest and replaced<br />

with fresh oil.<br />

-- The stated period can only be attained when the crankcase is sealed during the preservation period in accordance with the preservation<br />

requirements.<br />

-- After changing the oil, turn the compressor and the engine or run them for the required period. See paras. 6.2. and 6.5<br />

-- Check the lubrication of the compressor when putting the unit into operation once every six months or when turning the compressor.<br />

The oil pump is functioning properly when oil can be seen flowing through the sight glass of the oil pressure regulator and if the oil<br />

pressure gauge indicates the prescribed pressure.<br />

6.6. REACTIVATING THE COMPRESSOR UNIT<br />

-- Remove the dust cap from the inlet port and insert the intake filter.<br />

-- Check the oil level of the compressor.<br />

-- Check the motor/engine according to the manufacturer’s instructions.<br />

-- Turn the compressor unit a few times by hand.<br />

-- Run the compressor warm with open filling valves or outlet valve for approx. 10 minutes.<br />

-- Check the oil flow through the sight glass or oil pressure on the pressure gauge. If there is any fault, check the lubrication of the<br />

compressor.<br />

-- After 10 minutes, close the filling valves or the outlet valve and run the unit up to final pressure until the final pressure safety valve<br />

blows. To do so, override the pressure switch, if installed on the unit. On units with a built in compressor control put the S3 service<br />

switch on position ON.<br />

-- Check the intermediate--pressure safety valves for leakage.<br />

-- Establish cause of any fault from the trouble--shooting table and remedy.<br />

-- On units, equipped with a filter system, please note:<br />

open purifier and replace filter cartridge.<br />

-- Stop the system when running properly, the compressor is then ready for operation.