Operator’s <strong>Manual</strong><br />

3.8. SHUT -DOWN PROCEDURE<br />

-- Close filling valves.<br />

Units with electric motor:<br />

-- Alternating current: Position 0--1 control switch on engine to 0.<br />

-- Three--phase current: Master switch must be OFF (to be supplied by customer).<br />

-- Press control button 0 on the control-- and monitoring unit. Place main switch to position OFF.<br />

-- When servicing the compressor or the electrical control unit switch the master switch (provided by customer) to OFF.<br />

Units with petrol or diesel engines:<br />

-- Shut down petrol engine with stop button, close fuel shut--off valve.<br />

-- Shut down diesel engine with stop lever, close fuel shut--off valve.<br />

-- Open condensate drain valves until no more condensate comes out. Then close all valves again and leave unit with residual<br />

pressure, so that no moisture can penetrate into the unit.<br />

-- Check the oil level in the compressor and top up, if necessary. Also check whether the compressor needs servicing in accordance<br />

with maintenance schedule -- see next chapter.<br />