Operator’s <strong>Manual</strong><br />

3.6.2. Starting the unit<br />

NOTE<br />

Knocking, audible when starting, is due to last stage floating piston. This knocking disappears as soon as there<br />

is pressure between the stages and the piston is running synchronous with the other pistons. Therefore, this<br />

knocking can be ignored.<br />

Units with electric drive motor:<br />

-- Alternating current: Position 0--1 control switch on engine to 1.<br />

-- Three--phase current: Master switch must be ON (to be supplied by customer).<br />

-- Depending on model, either set 0 --I switch at switch box to I, or press the I button on the control and monitoring unit.<br />

-- (Units with electronic monitoring unit):<br />

Start--up of the compressor is indicated by the pilot light illuminating on the Electronic Control which must extinguish once the<br />

specified operating conditions have been attained.<br />

-- Observe the pressure switch shut--off pressure on units with automatic compressor control.<br />

-- If final pressure is reached and pressure switch shuts off unit properly, open condensate drain valves and drain condensate. Unit<br />

is then ready for filling operation.<br />

Units with petrol or diesel engine<br />

-- Open condensate drain valves on the filters so that motor starts without load.<br />

-- Set choke on petrol engine to position START. Start engine with recoil starter or crank handle. As soon as motor runs smoothly<br />

return choke to normal operating position.<br />

-- Close condensate drain valves and run unit to final pressure. Check final pressure safety valve and pressure gauge.<br />

-- As soon as final pressure is reached and final pressure safety valve blows off, open condensate drain valves and drain condensate<br />

-- unit is ready for filling operation.<br />