3.4. ARTIFICIAL VENTILATION<br />
20<br />
Operator’s <strong>Manual</strong><br />
For drive powers above 15 kW natural ventilation is not sufficient. Under certain circumstances this can also apply for smaller power<br />
ratings, e.g.:<br />
-- when locating the compressor in small rooms,<br />
-- if ventilation openings cannot be large enough,<br />
-- when other systems with high heat radiation are operating in the same room or<br />
-- when two or more compressors are operating in the same room.<br />
The principle is: forced ventilation is obligatory if room temperature exceeds the allowed ambient temperature<br />
(45° C)<br />
Cooling air flow<br />
The necessary cooling air flow is calculated to an appoximate value by using the following formula:<br />
Required minimum cooling air volume [m 3 /h] = 360 x drive power [kW]<br />
For calculation of the cooling air duct cross section the following formula can be used:<br />
Cooling air duct [m2 ] = cooling air volume [m3 /h]<br />
cooling air flow [m/s] x 3600 [s/h]<br />
The recommended cooling air flow is approx. 3 to 5 m/s, but max. 10 m/s.<br />
Example: Verticus III, drive power 11 kW:<br />
Cooling air volume = 360 x 11 = 3960 m 3 /h<br />
Cross section =<br />
Methods<br />
3960 m3 /h<br />
3 m/s x 3600 s/h<br />
=0.36m 2<br />
There are several types of artificial ventilation:<br />
-- free air flow effected by a blower<br />
-- ventilation by means of an air channel with or without additional blowera) -- ventilation by means of an air circulating flap with or without additional blowera) If installed correctly, the free air flow cooling method should be sufficient for all VERTICUS compressor units.<br />
a) ATTENTION: Ensure that the max. counter -pressure in the intake and outlet channels Δ p = 0.5 mbar = 5 mm W.G. (measured at a distance<br />
of 1 m from the compressor unit) is not exceeded.