18<br />
Power<br />
(kW)<br />
V=50m 3<br />
Δh =2m<br />
Room volume / Height difference<br />
V = 100 m 3<br />
Δh =3m<br />
Operator’s <strong>Manual</strong><br />
V = 200 m 3<br />
Δh =4m<br />
Intake Outlet Intake Outlet Intake Outlet<br />
2.2 0.12 m 2 0.10 m 2 -- -- -- -- -- -- -- --<br />
3 0.24 m 2 0.20 m 2 0.12 m 2 0.10 m 2 -- -- -- --<br />
4 0.30 m 2 0.25 m 2 0.12 m 2 0.10 m 2 -- -- -- --<br />
5.5 0.42 m 2 0.35 m 2 0.24 m 2 0.20 m 2 0.12 m 2 0.10 m 2<br />
7.5 0.90 m 2 0.75 m 2 0.60 m 2 0.50 m 2 0.24 m 2 0.20 m 2<br />
11 1.38 m 2 1.15 m 2 0.90 m 2 0.75 m 2 0.54 m 2 0.45 m 2<br />
15 1.92 m 2 1.60 m 2 1.45 m 2 1.20 m 2 0.90 m 2 0.75 m 2<br />
Tab. 1 <strong>Air</strong> intake and outlet openings<br />
Fig. 12 to Fig. 14 show installation examples with natural ventilation:<br />
Correct: <strong>Air</strong> intake low, cooling air flows though<br />
unit<br />
Fig. 12 Installation with natural ventilation, example 1<br />
Incorrect: <strong>Air</strong> intake high, cooling air does not<br />
reach unit